Add opentherm_gw binary sensor support (#17625)

* Add OpenTherm Gateway binary sensor support.

* opentherm_gw binary_sensor platform does not need polling.
This commit is contained in:
mvn23 authored and Martin Hjelmare committed 2018-10-20 18:51:01 +02:00
1 parent 2e973c7572
commit 237ac08076
2 files changed
+191 -3

No files matched your search

@@ -0,0 +1,145 @@
"""
Support for OpenTherm Gateway binary sensors.
For more details about this platform, please refer to the documentation at
http://home-assistant.io/components/binary_sensor.opentherm_gw/
"""
import logging
from homeassistant.components.binary_sensor import (
BinarySensorDevice, ENTITY_ID_FORMAT)
from homeassistant.components.opentherm_gw import (
DATA_GW_VARS, DATA_OPENTHERM_GW, SIGNAL_OPENTHERM_GW_UPDATE)
from homeassistant.helpers.dispatcher import async_dispatcher_connect
from homeassistant.helpers.entity import async_generate_entity_id
DEVICE_CLASS_COLD = 'cold'
DEVICE_CLASS_HEAT = 'heat'
DEVICE_CLASS_PROBLEM = 'problem'
DEPENDENCIES = ['opentherm_gw']
_LOGGER = logging.getLogger(__name__)
async def async_setup_platform(hass, config, async_add_entities,
discovery_info=None):
"""Set up the OpenTherm Gateway binary sensors."""
if discovery_info is None:
return
gw_vars = hass.data[DATA_OPENTHERM_GW][DATA_GW_VARS]
sensor_info = {
# [device_class, friendly_name]
gw_vars.DATA_MASTER_CH_ENABLED: [
None, "Thermostat Central Heating Enabled"],
gw_vars.DATA_MASTER_DHW_ENABLED: [
None, "Thermostat Hot Water Enabled"],
gw_vars.DATA_MASTER_COOLING_ENABLED: [
None, "Thermostat Cooling Enabled"],
gw_vars.DATA_MASTER_OTC_ENABLED: [
None, "Thermostat Outside Temperature Correction Enabled"],
gw_vars.DATA_MASTER_CH2_ENABLED: [
None, "Thermostat Central Heating 2 Enabled"],
gw_vars.DATA_SLAVE_FAULT_IND: [
DEVICE_CLASS_PROBLEM, "Boiler Fault Indication"],
gw_vars.DATA_SLAVE_CH_ACTIVE: [
DEVICE_CLASS_HEAT, "Boiler Central Heating Status"],
gw_vars.DATA_SLAVE_DHW_ACTIVE: [
DEVICE_CLASS_HEAT, "Boiler Hot Water Status"],
gw_vars.DATA_SLAVE_FLAME_ON: [
DEVICE_CLASS_HEAT, "Boiler Flame Status"],
gw_vars.DATA_SLAVE_COOLING_ACTIVE: [
DEVICE_CLASS_COLD, "Boiler Cooling Status"],
gw_vars.DATA_SLAVE_CH2_ACTIVE: [
DEVICE_CLASS_HEAT, "Boiler Central Heating 2 Status"],
gw_vars.DATA_SLAVE_DIAG_IND: [
DEVICE_CLASS_PROBLEM, "Boiler Diagnostics Indication"],
gw_vars.DATA_SLAVE_DHW_PRESENT: [None, "Boiler Hot Water Present"],
gw_vars.DATA_SLAVE_CONTROL_TYPE: [None, "Boiler Control Type"],
gw_vars.DATA_SLAVE_COOLING_SUPPORTED: [None, "Boiler Cooling Support"],
gw_vars.DATA_SLAVE_DHW_CONFIG: [
None, "Boiler Hot Water Configuration"],
gw_vars.DATA_SLAVE_MASTER_LOW_OFF_PUMP: [
None, "Boiler Pump Commands Support"],
gw_vars.DATA_SLAVE_CH2_PRESENT: [
None, "Boiler Central Heating 2 Present"],
gw_vars.DATA_SLAVE_SERVICE_REQ: [
DEVICE_CLASS_PROBLEM, "Boiler Service Required"],
gw_vars.DATA_SLAVE_REMOTE_RESET: [None, "Boiler Remote Reset Support"],
gw_vars.DATA_SLAVE_LOW_WATER_PRESS: [
DEVICE_CLASS_PROBLEM, "Boiler Low Water Pressure"],
gw_vars.DATA_SLAVE_GAS_FAULT: [
DEVICE_CLASS_PROBLEM, "Boiler Gas Fault"],
gw_vars.DATA_SLAVE_AIR_PRESS_FAULT: [
DEVICE_CLASS_PROBLEM, "Boiler Air Pressure Fault"],
gw_vars.DATA_SLAVE_WATER_OVERTEMP: [
DEVICE_CLASS_PROBLEM, "Boiler Water Overtemperature"],
gw_vars.DATA_REMOTE_TRANSFER_DHW: [
None, "Remote Hot Water Setpoint Transfer Support"],
gw_vars.DATA_REMOTE_TRANSFER_MAX_CH: [
None, "Remote Maximum Central Heating Setpoint Write Support"],
gw_vars.DATA_REMOTE_RW_DHW: [
None, "Remote Hot Water Setpoint Write Support"],
gw_vars.DATA_REMOTE_RW_MAX_CH: [
None, "Remote Central Heating Setpoint Write Support"],
gw_vars.DATA_ROVRD_MAN_PRIO: [
None, "Remote Override Manual Change Priority"],
gw_vars.DATA_ROVRD_AUTO_PRIO: [
None, "Remote Override Program Change Priority"],
gw_vars.OTGW_GPIO_A_STATE: [None, "Gateway GPIO A State"],
gw_vars.OTGW_GPIO_B_STATE: [None, "Gateway GPIO B State"],
gw_vars.OTGW_IGNORE_TRANSITIONS: [None, "Gateway Ignore Transitions"],
gw_vars.OTGW_OVRD_HB: [None, "Gateway Override High Byte"],
}
sensors = []
for var in discovery_info:
device_class = sensor_info[var][0]
friendly_name = sensor_info[var][1]
entity_id = async_generate_entity_id(ENTITY_ID_FORMAT, var, hass=hass)
sensors.append(OpenThermBinarySensor(entity_id, var, device_class,
friendly_name))
async_add_entities(sensors)
class OpenThermBinarySensor(BinarySensorDevice):
"""Represent an OpenTherm Gateway binary sensor."""
def __init__(self, entity_id, var, device_class, friendly_name):
"""Initialize the binary sensor."""
self.entity_id = entity_id
self._var = var
self._state = None
self._device_class = device_class
self._friendly_name = friendly_name
async def async_added_to_hass(self):
"""Subscribe to updates from the component."""
_LOGGER.debug(
"Added OpenTherm Gateway binary sensor %s", self._friendly_name)
async_dispatcher_connect(self.hass, SIGNAL_OPENTHERM_GW_UPDATE,
self.receive_report)
async def receive_report(self, status):
"""Handle status updates from the component."""
self._state = bool(status.get(self._var))
self.async_schedule_update_ha_state()
@property
def name(self):
"""Return the friendly name."""
return self._friendly_name
@property
def is_on(self):
"""Return true if the binary sensor is on."""
return self._state
@property
def device_class(self):
"""Return the class of this device."""
return self._device_class
@property
def should_poll(self):
"""Return False because entity pushes its state."""
return False