Correct units used in TP-Link energy monioring (#10979)
* Correct units used in TP-Link energy monioring - Energy is measured in kWh for swtches - Power is reported in mW for bulbs - Energy is reported in Wh for bulbs * TP-Ling energy: store units in attribute names Stores the unit in the attrbute names for TP-Link devices that support energy monitoring.
This commit is contained in:
1 parent
b635637541
commit
2a2e6b6334
2 files changed
+25
-25
No files matched your search
@@ -9,7 +9,8 @@ import time
|
||||
|
||||
import voluptuous as vol
|
||||
|
||||
from homeassistant.components.switch import (SwitchDevice, PLATFORM_SCHEMA)
|
||||
from homeassistant.components.switch import (
|
||||
SwitchDevice, PLATFORM_SCHEMA, ATTR_CURRENT_POWER_W, ATTR_TODAY_ENERGY_KWH)
|
||||
from homeassistant.const import (CONF_HOST, CONF_NAME, ATTR_VOLTAGE)
|
||||
import homeassistant.helpers.config_validation as cv
|
||||
|
||||
@@ -17,10 +18,8 @@ REQUIREMENTS = ['pyHS100==0.3.0']
|
||||
|
||||
_LOGGER = logging.getLogger(__name__)
|
||||
|
||||
ATTR_CURRENT_CONSUMPTION = 'current_consumption'
|
||||
ATTR_TOTAL_CONSUMPTION = 'total_consumption'
|
||||
ATTR_DAILY_CONSUMPTION = 'daily_consumption'
|
||||
ATTR_CURRENT = 'current'
|
||||
ATTR_TOTAL_ENERGY_KWH = 'total_energy_kwh'
|
||||
ATTR_CURRENT_A = 'current_a'
|
||||
|
||||
CONF_LEDS = 'enable_leds'
|
||||
|
||||
@@ -102,19 +101,20 @@ class SmartPlugSwitch(SwitchDevice):
|
||||
if self.smartplug.has_emeter:
|
||||
emeter_readings = self.smartplug.get_emeter_realtime()
|
||||
|
||||
self._emeter_params[ATTR_CURRENT_CONSUMPTION] \
|
||||
= "%.1f W" % emeter_readings["power"]
|
||||
self._emeter_params[ATTR_TOTAL_CONSUMPTION] \
|
||||
= "%.2f kW" % emeter_readings["total"]
|
||||
self._emeter_params[ATTR_CURRENT_POWER_W] \
|
||||
= "{:.2f}".format(emeter_readings["power"])
|
||||
self._emeter_params[ATTR_TOTAL_ENERGY_KWH] \
|
||||
= "{:.3f}".format(emeter_readings["total"])
|
||||
self._emeter_params[ATTR_VOLTAGE] \
|
||||
= "%.2f V" % emeter_readings["voltage"]
|
||||
self._emeter_params[ATTR_CURRENT] \
|
||||
= "%.1f A" % emeter_readings["current"]
|
||||
= "{:.1f}".format(emeter_readings["voltage"])
|
||||
self._emeter_params[ATTR_CURRENT_A] \
|
||||
= "{:.2f}".format(emeter_readings["current"])
|
||||
|
||||
emeter_statics = self.smartplug.get_emeter_daily()
|
||||
try:
|
||||
self._emeter_params[ATTR_DAILY_CONSUMPTION] \
|
||||
= "%.2f kW" % emeter_statics[int(time.strftime("%e"))]
|
||||
self._emeter_params[ATTR_TODAY_ENERGY_KWH] \
|
||||
= "{:.3f}".format(
|
||||
emeter_statics[int(time.strftime("%e"))])
|
||||
except KeyError:
|
||||
# Device returned no daily history
|
||||
pass
|
||||
|
||||
Reference in new issue