Fix MELCloud temperature unit (#35003)

The MELCLoud API produces and consumes only Celsius.
This commit is contained in:
Vilppu Vuorinen authored and GitHub committed 2020-05-01 13:33:46 +02:00
1 parent 8ec5e53cf4
commit 66d3832be9
4 files changed
+16 -31

No files matched your search

+8 -8
View File
@@ -12,11 +12,11 @@ from homeassistant.const import (
from homeassistant.helpers.entity import Entity
from . import MelCloudDevice
from .const import DOMAIN, TEMP_UNIT_LOOKUP
from .const import DOMAIN
ATTR_MEASUREMENT_NAME = "measurement_name"
ATTR_ICON = "icon"
ATTR_UNIT_FN = "unit_fn"
ATTR_UNIT = "unit"
ATTR_DEVICE_CLASS = "device_class"
ATTR_VALUE_FN = "value_fn"
ATTR_ENABLED_FN = "enabled"
@@ -25,7 +25,7 @@ ATA_SENSORS = {
"room_temperature": {
ATTR_MEASUREMENT_NAME: "Room Temperature",
ATTR_ICON: "mdi:thermometer",
ATTR_UNIT_FN: lambda x: TEMP_UNIT_LOOKUP.get(x.device.temp_unit, TEMP_CELSIUS),
ATTR_UNIT: TEMP_CELSIUS,
ATTR_DEVICE_CLASS: DEVICE_CLASS_TEMPERATURE,
ATTR_VALUE_FN: lambda x: x.device.room_temperature,
ATTR_ENABLED_FN: lambda x: True,
@@ -33,7 +33,7 @@ ATA_SENSORS = {
"energy": {
ATTR_MEASUREMENT_NAME: "Energy",
ATTR_ICON: "mdi:factory",
ATTR_UNIT_FN: lambda x: ENERGY_KILO_WATT_HOUR,
ATTR_UNIT: ENERGY_KILO_WATT_HOUR,
ATTR_DEVICE_CLASS: None,
ATTR_VALUE_FN: lambda x: x.device.total_energy_consumed,
ATTR_ENABLED_FN: lambda x: x.device.has_energy_consumed_meter,
@@ -43,7 +43,7 @@ ATW_SENSORS = {
"outside_temperature": {
ATTR_MEASUREMENT_NAME: "Outside Temperature",
ATTR_ICON: "mdi:thermometer",
ATTR_UNIT_FN: lambda x: TEMP_UNIT_LOOKUP.get(x.device.temp_unit, TEMP_CELSIUS),
ATTR_UNIT: TEMP_CELSIUS,
ATTR_DEVICE_CLASS: DEVICE_CLASS_TEMPERATURE,
ATTR_VALUE_FN: lambda x: x.device.outside_temperature,
ATTR_ENABLED_FN: lambda x: True,
@@ -51,7 +51,7 @@ ATW_SENSORS = {
"tank_temperature": {
ATTR_MEASUREMENT_NAME: "Tank Temperature",
ATTR_ICON: "mdi:thermometer",
ATTR_UNIT_FN: lambda x: TEMP_UNIT_LOOKUP.get(x.device.temp_unit, TEMP_CELSIUS),
ATTR_UNIT: TEMP_CELSIUS,
ATTR_DEVICE_CLASS: DEVICE_CLASS_TEMPERATURE,
ATTR_VALUE_FN: lambda x: x.device.tank_temperature,
ATTR_ENABLED_FN: lambda x: True,
@@ -61,7 +61,7 @@ ATW_ZONE_SENSORS = {
"room_temperature": {
ATTR_MEASUREMENT_NAME: "Room Temperature",
ATTR_ICON: "mdi:thermometer",
ATTR_UNIT_FN: lambda x: TEMP_UNIT_LOOKUP.get(x.device.temp_unit, TEMP_CELSIUS),
ATTR_UNIT: TEMP_CELSIUS,
ATTR_DEVICE_CLASS: DEVICE_CLASS_TEMPERATURE,
ATTR_VALUE_FN: lambda zone: zone.room_temperature,
ATTR_ENABLED_FN: lambda x: True,
@@ -147,7 +147,7 @@ class MelDeviceSensor(Entity):
@property
def unit_of_measurement(self):
"""Return the unit of measurement."""
return self._def[ATTR_UNIT_FN](self._api)
return self._def[ATTR_UNIT]
@property
def device_class(self):