@@ -240,15 +240,22 @@ class MqttClimate(MqttAvailability, MqttDiscoveryUpdate, ClimateDevice):
|
||||
self._value_templates = value_templates
|
||||
self._qos = qos
|
||||
self._retain = retain
|
||||
self._target_temperature = target_temperature
|
||||
# set to None in non-optimistic mode
|
||||
self._target_temperature = self._current_fan_mode = \
|
||||
self._current_operation = self._current_swing_mode = None
|
||||
if self._topic[CONF_TEMPERATURE_STATE_TOPIC] is None:
|
||||
self._target_temperature = target_temperature
|
||||
self._unit_of_measurement = hass.config.units.temperature_unit
|
||||
self._away = away
|
||||
self._hold = hold
|
||||
self._current_temperature = None
|
||||
self._current_fan_mode = current_fan_mode
|
||||
self._current_operation = current_operation
|
||||
if self._topic[CONF_FAN_MODE_STATE_TOPIC] is None:
|
||||
self._current_fan_mode = current_fan_mode
|
||||
if self._topic[CONF_MODE_STATE_TOPIC] is None:
|
||||
self._current_operation = current_operation
|
||||
self._aux = aux
|
||||
self._current_swing_mode = current_swing_mode
|
||||
if self._topic[CONF_SWING_MODE_STATE_TOPIC] is None:
|
||||
self._current_swing_mode = current_swing_mode
|
||||
self._fan_list = fan_mode_list
|
||||
self._operation_list = mode_list
|
||||
self._swing_list = swing_mode_list
|
||||
|
||||
Reference in new issue