Fixed the z-wave sensor workarounds for empty manufacturer ids
This commit is contained in:
1 parent
e92c77a113
commit
c586111c8c
2 files changed
+29
-22
No files matched your search
@@ -50,17 +50,20 @@ def setup_platform(hass, config, add_devices, discovery_info=None):
|
||||
# groups[1].associations):
|
||||
# node.groups[1].add_association(NETWORK.controller.node_id)
|
||||
|
||||
specific_sensor_key = (int(value.node.manufacturer_id, 16),
|
||||
int(value.node.product_id, 16),
|
||||
value.index)
|
||||
# Make sure that we have values for the key before converting to int
|
||||
if (value.node.manufacturer_id.strip() and
|
||||
value.node.product_id.strip()):
|
||||
specific_sensor_key = (int(value.node.manufacturer_id, 16),
|
||||
int(value.node.product_id, 16),
|
||||
value.index)
|
||||
|
||||
# Check workaround mappings for specific devices.
|
||||
if specific_sensor_key in DEVICE_MAPPINGS:
|
||||
if DEVICE_MAPPINGS[specific_sensor_key] == WORKAROUND_IGNORE:
|
||||
return
|
||||
# Check workaround mappings for specific devices.
|
||||
if specific_sensor_key in DEVICE_MAPPINGS:
|
||||
if DEVICE_MAPPINGS[specific_sensor_key] == WORKAROUND_IGNORE:
|
||||
return
|
||||
|
||||
# Generic Device mappings
|
||||
elif value.command_class == COMMAND_CLASS_SENSOR_MULTILEVEL:
|
||||
if value.command_class == COMMAND_CLASS_SENSOR_MULTILEVEL:
|
||||
add_devices([ZWaveMultilevelSensor(value)])
|
||||
|
||||
elif (value.command_class == COMMAND_CLASS_METER and
|
||||
|
||||
Reference in new issue
Block a user