Don't use len(SEQUENCE) as condition value (#7249)

* Don't use len(SEQUENCE) as condition value

* Update volvooncall.py
This commit is contained in:
Fabian Affolter authored and Paulus Schoutsen committed 2017-04-23 20:41:09 -07:00
1 parent 15b2473224
commit cfc023e128
43 files changed
+319 -355

No files matched your search

+6 -6
View File
@@ -1,4 +1,3 @@
"""
Support for the Broadlink RM2 Pro (only temperature) and A1 devices.
@@ -9,12 +8,13 @@ from datetime import timedelta
import binascii
import logging
import socket
import voluptuous as vol
from homeassistant.components.sensor import PLATFORM_SCHEMA
from homeassistant.const import (CONF_HOST, CONF_MAC,
CONF_MONITORED_CONDITIONS,
CONF_NAME, TEMP_CELSIUS, CONF_TIMEOUT)
from homeassistant.const import (
CONF_HOST, CONF_MAC, CONF_MONITORED_CONDITIONS, CONF_NAME, TEMP_CELSIUS,
CONF_TIMEOUT)
from homeassistant.helpers.entity import Entity
from homeassistant.util import Throttle
import homeassistant.helpers.config_validation as cv
@@ -71,7 +71,7 @@ class BroadlinkSensor(Entity):
def __init__(self, name, broadlink_data, sensor_type):
"""Initialize the sensor."""
self._name = "%s %s" % (name, SENSOR_TYPES[sensor_type][0])
self._name = '{} {}'.format(name, SENSOR_TYPES[sensor_type][0])
self._state = None
self._type = sensor_type
self._broadlink_data = broadlink_data
@@ -119,7 +119,7 @@ class BroadlinkData(object):
})
self.update = Throttle(interval)(self._update)
if not self._auth():
_LOGGER.warning("Failed to connect to device.")
_LOGGER.warning("Failed to connect to device")
def _update(self, retry=3):