Correct calculation and units of light level values. (#23309)
This commit is contained in:
1 parent
f514d44224
commit
df3ceb8d87
2 files changed
+12
-7
No files matched your search
@@ -27,12 +27,17 @@ class HueLightLevel(GenericHueGaugeSensorEntity):
|
||||
"""The light level sensor entity for a Hue motion sensor device."""
|
||||
|
||||
device_class = DEVICE_CLASS_ILLUMINANCE
|
||||
unit_of_measurement = "Lux"
|
||||
unit_of_measurement = "lx"
|
||||
|
||||
@property
|
||||
def state(self):
|
||||
"""Return the state of the device."""
|
||||
return self.sensor.lightlevel
|
||||
# https://developers.meethue.com/develop/hue-api/supported-devices/#clip_zll_lightlevel
|
||||
# Light level in 10000 log10 (lux) +1 measured by sensor. Logarithm
|
||||
# scale used because the human eye adjusts to light levels and small
|
||||
# changes at low lux levels are more noticeable than at high lux
|
||||
# levels.
|
||||
return 10 ** ((self.sensor.lightlevel - 1) / 10000)
|
||||
|
||||
@property
|
||||
def device_state_attributes(self):
|
||||
|
||||