Update KNX component to xknx 0.11 (#24738)

* update component for xknx 0.11.0

- expose sensor state is not casted to float anymore
- climate mode operation list has no more None values
- light supports white_value (rgbw)
- sensor expects `group_address_state` now instead of `group_address`
- sensor forwards device_class if available

* update manifest to use xknx 0.11.0

* update requirements_all for xknx 0.11.0

* update for xknx 0.11.1

- require xknx 0.11.1
- use 'state_address' instead of 'address' in sensor and binary_sensor configuration
- optional 'sync_state' for sensors and binary_sensors

* remove questionable `del kwargs`
This commit is contained in:
Matthias Alphart authored and Martin Hjelmare committed 2019-07-11 22:01:37 +02:00
1 parent 78a5dc71ac
commit e299d7b3d6
11 files changed
+108 -66

No files matched your search

+13 -9
View File
@@ -3,14 +3,16 @@ import voluptuous as vol
from homeassistant.components.binary_sensor import (
PLATFORM_SCHEMA, BinarySensorDevice)
from homeassistant.const import CONF_ADDRESS, CONF_DEVICE_CLASS, CONF_NAME
from homeassistant.const import CONF_DEVICE_CLASS, CONF_NAME
from homeassistant.core import callback
import homeassistant.helpers.config_validation as cv
from . import ATTR_DISCOVER_DEVICES, DATA_KNX, KNXAutomation
CONF_STATE_ADDRESS = 'state_address'
CONF_SIGNIFICANT_BIT = 'significant_bit'
CONF_DEFAULT_SIGNIFICANT_BIT = 1
CONF_SYNC_STATE = 'sync_state'
CONF_AUTOMATION = 'automation'
CONF_HOOK = 'hook'
CONF_DEFAULT_HOOK = 'on'
@@ -31,11 +33,12 @@ AUTOMATION_SCHEMA = vol.Schema({
AUTOMATIONS_SCHEMA = vol.All(cv.ensure_list, [AUTOMATION_SCHEMA])
PLATFORM_SCHEMA = PLATFORM_SCHEMA.extend({
vol.Required(CONF_ADDRESS): cv.string,
vol.Optional(CONF_NAME, default=DEFAULT_NAME): cv.string,
vol.Optional(CONF_DEVICE_CLASS): cv.string,
vol.Optional(CONF_SIGNIFICANT_BIT, default=CONF_DEFAULT_SIGNIFICANT_BIT):
cv.positive_int,
vol.Optional(CONF_SYNC_STATE, default=True): cv.boolean,
vol.Required(CONF_STATE_ADDRESS): cv.string,
vol.Optional(CONF_DEVICE_CLASS): cv.string,
vol.Optional(CONF_RESET_AFTER): cv.positive_int,
vol.Optional(CONF_AUTOMATION): AUTOMATIONS_SCHEMA,
})
@@ -63,14 +66,15 @@ def async_add_entities_discovery(hass, discovery_info, async_add_entities):
@callback
def async_add_entities_config(hass, config, async_add_entities):
"""Set up binary senor for KNX platform configured within platform."""
name = config.get(CONF_NAME)
name = config[CONF_NAME]
import xknx
binary_sensor = xknx.devices.BinarySensor(
hass.data[DATA_KNX].xknx,
name=name,
group_address=config.get(CONF_ADDRESS),
group_address_state=config[CONF_STATE_ADDRESS],
sync_state=config[CONF_SYNC_STATE],
device_class=config.get(CONF_DEVICE_CLASS),
significant_bit=config.get(CONF_SIGNIFICANT_BIT),
significant_bit=config[CONF_SIGNIFICANT_BIT],
reset_after=config.get(CONF_RESET_AFTER))
hass.data[DATA_KNX].xknx.devices.add(binary_sensor)
@@ -78,9 +82,9 @@ def async_add_entities_config(hass, config, async_add_entities):
automations = config.get(CONF_AUTOMATION)
if automations is not None:
for automation in automations:
counter = automation.get(CONF_COUNTER)
hook = automation.get(CONF_HOOK)
action = automation.get(CONF_ACTION)
counter = automation[CONF_COUNTER]
hook = automation[CONF_HOOK]
action = automation[CONF_ACTION]
entity.automations.append(KNXAutomation(
hass=hass, device=binary_sensor, hook=hook,
action=action, counter=counter))