Update KNX component to xknx 0.11 (#24738)
* update component for xknx 0.11.0 - expose sensor state is not casted to float anymore - climate mode operation list has no more None values - light supports white_value (rgbw) - sensor expects `group_address_state` now instead of `group_address` - sensor forwards device_class if available * update manifest to use xknx 0.11.0 * update requirements_all for xknx 0.11.0 * update for xknx 0.11.1 - require xknx 0.11.1 - use 'state_address' instead of 'address' in sensor and binary_sensor configuration - optional 'sync_state' for sensors and binary_sensors * remove questionable `del kwargs`
This commit is contained in:
1 parent
78a5dc71ac
commit
e299d7b3d6
11 files changed
+108
-66
No files matched your search
@@ -69,11 +69,6 @@ PRESET_MODES_INV = dict((
|
||||
|
||||
PLATFORM_SCHEMA = PLATFORM_SCHEMA.extend({
|
||||
vol.Optional(CONF_NAME, default=DEFAULT_NAME): cv.string,
|
||||
vol.Required(CONF_TEMPERATURE_ADDRESS): cv.string,
|
||||
vol.Required(CONF_TARGET_TEMPERATURE_STATE_ADDRESS): cv.string,
|
||||
vol.Optional(CONF_TARGET_TEMPERATURE_ADDRESS): cv.string,
|
||||
vol.Optional(CONF_SETPOINT_SHIFT_ADDRESS): cv.string,
|
||||
vol.Optional(CONF_SETPOINT_SHIFT_STATE_ADDRESS): cv.string,
|
||||
vol.Optional(CONF_SETPOINT_SHIFT_STEP,
|
||||
default=DEFAULT_SETPOINT_SHIFT_STEP): vol.All(
|
||||
float, vol.Range(min=0, max=2)),
|
||||
@@ -81,6 +76,11 @@ PLATFORM_SCHEMA = PLATFORM_SCHEMA.extend({
|
||||
vol.All(int, vol.Range(min=0, max=32)),
|
||||
vol.Optional(CONF_SETPOINT_SHIFT_MIN, default=DEFAULT_SETPOINT_SHIFT_MIN):
|
||||
vol.All(int, vol.Range(min=-32, max=0)),
|
||||
vol.Required(CONF_TEMPERATURE_ADDRESS): cv.string,
|
||||
vol.Required(CONF_TARGET_TEMPERATURE_STATE_ADDRESS): cv.string,
|
||||
vol.Optional(CONF_TARGET_TEMPERATURE_ADDRESS): cv.string,
|
||||
vol.Optional(CONF_SETPOINT_SHIFT_ADDRESS): cv.string,
|
||||
vol.Optional(CONF_SETPOINT_SHIFT_STATE_ADDRESS): cv.string,
|
||||
vol.Optional(CONF_OPERATION_MODE_ADDRESS): cv.string,
|
||||
vol.Optional(CONF_OPERATION_MODE_STATE_ADDRESS): cv.string,
|
||||
vol.Optional(CONF_CONTROLLER_STATUS_ADDRESS): cv.string,
|
||||
@@ -125,7 +125,7 @@ def async_add_entities_config(hass, config, async_add_entities):
|
||||
|
||||
climate_mode = xknx.devices.ClimateMode(
|
||||
hass.data[DATA_KNX].xknx,
|
||||
name=config.get(CONF_NAME) + " Mode",
|
||||
name=config[CONF_NAME] + " Mode",
|
||||
group_address_operation_mode=config.get(CONF_OPERATION_MODE_ADDRESS),
|
||||
group_address_operation_mode_state=config.get(
|
||||
CONF_OPERATION_MODE_STATE_ADDRESS),
|
||||
@@ -149,7 +149,7 @@ def async_add_entities_config(hass, config, async_add_entities):
|
||||
|
||||
climate = xknx.devices.Climate(
|
||||
hass.data[DATA_KNX].xknx,
|
||||
name=config.get(CONF_NAME),
|
||||
name=config[CONF_NAME],
|
||||
group_address_temperature=config[CONF_TEMPERATURE_ADDRESS],
|
||||
group_address_target_temperature=config.get(
|
||||
CONF_TARGET_TEMPERATURE_ADDRESS),
|
||||
@@ -158,9 +158,9 @@ def async_add_entities_config(hass, config, async_add_entities):
|
||||
group_address_setpoint_shift=config.get(CONF_SETPOINT_SHIFT_ADDRESS),
|
||||
group_address_setpoint_shift_state=config.get(
|
||||
CONF_SETPOINT_SHIFT_STATE_ADDRESS),
|
||||
setpoint_shift_step=config.get(CONF_SETPOINT_SHIFT_STEP),
|
||||
setpoint_shift_max=config.get(CONF_SETPOINT_SHIFT_MAX),
|
||||
setpoint_shift_min=config.get(CONF_SETPOINT_SHIFT_MIN),
|
||||
setpoint_shift_step=config[CONF_SETPOINT_SHIFT_STEP],
|
||||
setpoint_shift_max=config[CONF_SETPOINT_SHIFT_MAX],
|
||||
setpoint_shift_min=config[CONF_SETPOINT_SHIFT_MIN],
|
||||
group_address_on_off=config.get(CONF_ON_OFF_ADDRESS),
|
||||
group_address_on_off_state=config.get(CONF_ON_OFF_STATE_ADDRESS),
|
||||
min_temp=config.get(CONF_MIN_TEMP),
|
||||
|
||||
Reference in new issue