Fix mFi sensors in uninitialized state (#3246)
If mFi sensors are identified but not fully assigned they can have no tag value, and mficlient throws a ValueError to signal this. This patch handles that case by considering such devices to always be STATE_OFF.
This commit is contained in:
1 parent
9d4ccb1f49
commit
f55095df83
2 files changed
+25
-4
No files matched your search
@@ -91,7 +91,13 @@ class MfiSensor(Entity):
|
||||
@property
|
||||
def state(self):
|
||||
"""Return the state of the sensor."""
|
||||
if self._port.model == 'Input Digital':
|
||||
try:
|
||||
tag = self._port.tag
|
||||
except ValueError:
|
||||
tag = None
|
||||
if tag is None:
|
||||
return STATE_OFF
|
||||
elif self._port.model == 'Input Digital':
|
||||
return self._port.value > 0 and STATE_ON or STATE_OFF
|
||||
else:
|
||||
digits = DIGITS.get(self._port.tag, 0)
|
||||
@@ -100,13 +106,18 @@ class MfiSensor(Entity):
|
||||
@property
|
||||
def unit_of_measurement(self):
|
||||
"""Return the unit of measurement of this entity, if any."""
|
||||
if self._port.tag == 'temperature':
|
||||
try:
|
||||
tag = self._port.tag
|
||||
except ValueError:
|
||||
return 'State'
|
||||
|
||||
if tag == 'temperature':
|
||||
return TEMP_CELSIUS
|
||||
elif self._port.tag == 'active_pwr':
|
||||
elif tag == 'active_pwr':
|
||||
return 'Watts'
|
||||
elif self._port.model == 'Input Digital':
|
||||
return 'State'
|
||||
return self._port.tag
|
||||
return tag
|
||||
|
||||
def update(self):
|
||||
"""Get the latest data."""
|
||||
|
||||
Reference in new issue