* Alexa: implement auth and proactive ChangeReport messages
* refactor after rebase from dev to use the new AlexaDirective and Response classes
* move to aiohttp; cleanup
* better function name
* move endpoint to config
* allow passing token function
* remove uneeded state get
* use iterable directly
Co-Authored-By: abmantis <abmantis@users.noreply.github.com>
* missing delete from previous commit
* checks for when user has no auth config
* update cloud component
* PR suggestions
* string lint
* Revert "string lint"
This reverts commit a05a1f134c9ebc7a6e67c093009744f142256365.
* linters are now happier
* more happy linters
* use internal date parser; improve json response handling
* remove unused import
* use await instead of async_add_job
* protect access token update method
* add test_report_state
* line too long
* add docstring
* Update test_smart_home.py
* test accept grant api
* init prefs if None
* add tests for auth and token requests
* replace global with hass.data
* doc lint
* awair: do not choke on no data
The awair API returns an empty response for various air data queries
when a device is offline. The underlying library (python_awair) does
not directly inform us that a device is offline, since we really can
only infer it from an empty response - there is no online/offline
indicator in the graphql API.
So - we should just ensure that we do not attempt to update device state
from an empty response. This ensures that the platform does not crash
when starting up with offline devices, and also ensures that the
platform is marked unavailable once devices go offline.
* Fix typo
Further proof that coding after 10pm is rolling the dice.
* Add ness alarm control panel using nessclient
* indenting
* .
* Remove availability functionality, will improve and add back in another PR
* Use call_count
* lint
* lint
* Review changes
* Lint
* Bump nessclient to 0.9.8
* Bump nessclient to 0.9.9
* Remove from .coveragerc
* some minor tests refactor
* async/await refactor
* toggle have not brightness
* test for race condition in unknown device
* test for 'no_command' and 'not_connected'
* test for race condition in unknown device
* sensor events are handled in sensor devices, RflinkDevice handle
command events
* test race conditions & bogus entity remove
* two more tests
* Test race condition for unknown components
* Test cleanup for `commands events` and `sensor events`
Rewrote the tests a bit
the 'wait for the timer to finish' part of the test is now it's own test.
The rest is a sequence of fire/assert. Which i rewrote to a loop to
reduce the amount of duplicate code
* Remove timer logic from sensor class
Proposed fix for issue #10500
* Updating the tests to remove timer logic
* Removing unecessary dependancy
* Fixing requested changes
* Commit to try to fix the CLA ?
* Disable creating port mappings from UI, add discovery from component
* Remove unused constant
* Upgrade to async_upnp_client==0.13.6 and use manufacturer from device
* Upgrade to async_upnp_client==0.13.7
* added new sensor platform to expose Islamic prayer times
* added new sensor platform to expose Islamic prayer times
* updated tests according to feedback
* make prayer_times_info a public attribute
* remove stale comments
* Add Mythic Beasts DNSAPI Component
* Added timeout, and tests for exceptions while updating
* Move API to external module
* Move mbddns import into function
* Updated tests to mock out mbddns library
* Add MVP
* Remove unused code
* Fix
* Add force back
* Fix tests
* Storage keyed
* Error out when storage doesnt find config
* Use old load_yaml
* Set config for panel correct
* Use instance cache var
* Make config option
* Set lock status correctly for Schlage BE469 Z-Wave locks
PR #17386 attempted to improve the state of z-wave lock tracking for
some problematic models. However, it operated under a flawed
assumptions. Namely, that we can always trust `self.values` to have
fresh data, and that the Schlage BE469 sends alarm reports after every
lock event. We can't trust `self.values`, and the Schlage is very
broken. :)
When we receive a notification from the driver about a state change,
we call `update_properties` - but we can (and do!) have _stale_
properties left over from previous updates. #17386 really works best
if you start from a clean slate each time. However, `update_properties`
is called on every value update, and we don't get a reason why.
Moreover, values that weren't just refreshed are not removed. So blindly
looking at something like `self.values.access_control` when deciding to
apply a workaround is not going to always be correct - it may or may not
be, depending on what happened in the past.
For the sad case of the BE469, here are the Z-Wave events that happen
under various circumstances:
RF Lock / Unlock:
- Send: door lock command set
- Receive: door lock report
- Send: door lock command get
- Receive: door lock report
Manual lock / Unlock:
- Receive: alarm
- Send: door lock command get
- Receive: door lock report
Keypad lock / Unlock:
- Receive: alarm
- Send: door lock command get
- Receive: door lock report
Thus, this PR introduces yet another work around - we track the current
and last z-wave command that the driver saw, and make assumptions based
on the sequence of events. This seems to be the most reliable way to go
- simply asking the driver to refresh various states doesn't clear out
alarms the way you would expect; this model doesn't support the access
control logging commands; and trying to manually clear out alarm state
when calling RF lock/unlock was tricky.
The lock state, when the z-wave network restarts, may look out of sync
for a few minutes. However, after the full network restart is complete,
everything looks good in my testing.
* Fix linter