Add climate platform to ozw (#35566)

This commit is contained in:
Marcel van der Veldt authored and GitHub committed 2020-05-21 11:19:20 +02:00
1 parent f5a326c51e
commit 5bef1c223d
7 files changed
+879 -1

No files matched your search

+339
View File
@@ -0,0 +1,339 @@
"""Support for Z-Wave climate devices."""
from enum import IntEnum
import logging
from typing import Optional, Tuple
from homeassistant.components.climate import DOMAIN as CLIMATE_DOMAIN, ClimateEntity
from homeassistant.components.climate.const import (
ATTR_TARGET_TEMP_HIGH,
ATTR_TARGET_TEMP_LOW,
CURRENT_HVAC_COOL,
CURRENT_HVAC_FAN,
CURRENT_HVAC_HEAT,
CURRENT_HVAC_IDLE,
CURRENT_HVAC_OFF,
HVAC_MODE_AUTO,
HVAC_MODE_COOL,
HVAC_MODE_DRY,
HVAC_MODE_FAN_ONLY,
HVAC_MODE_HEAT,
HVAC_MODE_HEAT_COOL,
HVAC_MODE_OFF,
PRESET_NONE,
SUPPORT_FAN_MODE,
SUPPORT_PRESET_MODE,
SUPPORT_TARGET_TEMPERATURE,
SUPPORT_TARGET_TEMPERATURE_RANGE,
)
from homeassistant.const import ATTR_TEMPERATURE, TEMP_CELSIUS, TEMP_FAHRENHEIT
from homeassistant.core import callback
from homeassistant.helpers.dispatcher import async_dispatcher_connect
from .const import DATA_UNSUBSCRIBE, DOMAIN
from .entity import ZWaveDeviceEntity
VALUE_LIST = "List"
VALUE_ID = "Value"
VALUE_LABEL = "Label"
VALUE_SELECTED_ID = "Selected_id"
VALUE_SELECTED_LABEL = "Selected"
ATTR_FAN_ACTION = "fan_action"
ATTR_VALVE_POSITION = "valve_position"
_LOGGER = logging.getLogger(__name__)
class ThermostatMode(IntEnum):
"""Enum with all (known/used) Z-Wave ThermostatModes."""
# https://github.com/OpenZWave/open-zwave/blob/master/cpp/src/command_classes/ThermostatMode.cpp
OFF = 0
HEAT = 1
COOL = 2
AUTO = 3
AUXILIARY = 4
RESUME_ON = 5
FAN = 6
FURNANCE = 7
DRY = 8
MOIST = 9
AUTO_CHANGE_OVER = 10
HEATING_ECON = 11
COOLING_ECON = 12
AWAY = 13
FULL_POWER = 15
MANUFACTURER_SPECIFIC = 31
MODE_SETPOINT_MAPPINGS = {
ThermostatMode.OFF: (),
ThermostatMode.HEAT: ("setpoint_heating",),
ThermostatMode.COOL: ("setpoint_cooling",),
ThermostatMode.AUTO: ("setpoint_heating", "setpoint_cooling"),
ThermostatMode.AUXILIARY: ("setpoint_heating",),
ThermostatMode.FURNANCE: ("setpoint_furnace",),
ThermostatMode.DRY: ("setpoint_dry_air",),
ThermostatMode.MOIST: ("setpoint_moist_air",),
ThermostatMode.AUTO_CHANGE_OVER: ("setpoint_auto_changeover",),
ThermostatMode.HEATING_ECON: ("setpoint_eco_heating",),
ThermostatMode.COOLING_ECON: ("setpoint_eco_cooling",),
ThermostatMode.AWAY: ("setpoint_away_heating", "setpoint_away_cooling"),
ThermostatMode.FULL_POWER: ("setpoint_full_power",),
}
# strings, OZW and/or qt-ozw does not send numeric values
# https://github.com/OpenZWave/open-zwave/blob/master/cpp/src/command_classes/ThermostatOperatingState.cpp
HVAC_CURRENT_MAPPINGS = {
"idle": CURRENT_HVAC_IDLE,
"heat": CURRENT_HVAC_HEAT,
"pending heat": CURRENT_HVAC_IDLE,
"heating": CURRENT_HVAC_HEAT,
"cool": CURRENT_HVAC_COOL,
"pending cool": CURRENT_HVAC_IDLE,
"cooling": CURRENT_HVAC_COOL,
"fan only": CURRENT_HVAC_FAN,
"vent / economiser": CURRENT_HVAC_FAN,
"off": CURRENT_HVAC_OFF,
}
# Map Z-Wave HVAC Mode to Home Assistant value
ZW_HVAC_MODE_MAPPINGS = {
ThermostatMode.OFF: HVAC_MODE_OFF,
ThermostatMode.HEAT: HVAC_MODE_HEAT,
ThermostatMode.COOL: HVAC_MODE_COOL,
ThermostatMode.AUTO: HVAC_MODE_AUTO,
ThermostatMode.AUXILIARY: HVAC_MODE_HEAT,
ThermostatMode.FAN: HVAC_MODE_FAN_ONLY,
ThermostatMode.FURNANCE: HVAC_MODE_HEAT,
ThermostatMode.DRY: HVAC_MODE_DRY,
ThermostatMode.AUTO_CHANGE_OVER: HVAC_MODE_HEAT_COOL,
ThermostatMode.HEATING_ECON: HVAC_MODE_HEAT,
ThermostatMode.COOLING_ECON: HVAC_MODE_COOL,
ThermostatMode.AWAY: HVAC_MODE_HEAT_COOL,
ThermostatMode.FULL_POWER: HVAC_MODE_HEAT,
}
# Map Home Assistant HVAC Mode to Z-Wave value
HVAC_MODE_ZW_MAPPINGS = {
HVAC_MODE_OFF: ThermostatMode.OFF,
HVAC_MODE_HEAT: ThermostatMode.HEAT,
HVAC_MODE_COOL: ThermostatMode.COOL,
HVAC_MODE_AUTO: ThermostatMode.AUTO,
HVAC_MODE_FAN_ONLY: ThermostatMode.FAN,
HVAC_MODE_DRY: ThermostatMode.DRY,
HVAC_MODE_HEAT_COOL: ThermostatMode.AUTO_CHANGE_OVER,
}
async def async_setup_entry(hass, config_entry, async_add_entities):
"""Set up Z-Wave Climate from Config Entry."""
@callback
def async_add_climate(values):
"""Add Z-Wave Climate."""
async_add_entities([ZWaveClimateEntity(values)])
hass.data[DOMAIN][config_entry.entry_id][DATA_UNSUBSCRIBE].append(
async_dispatcher_connect(
hass, f"{DOMAIN}_new_{CLIMATE_DOMAIN}", async_add_climate
)
)
class ZWaveClimateEntity(ZWaveDeviceEntity, ClimateEntity):
"""Representation of a Z-Wave Climate device."""
def __init__(self, values):
"""Initialize the entity."""
super().__init__(values)
self._current_mode_setpoint_values = self._get_current_mode_setpoint_values()
@callback
def on_value_update(self):
"""Call when the underlying value(s) is added or updated."""
self._current_mode_setpoint_values = self._get_current_mode_setpoint_values()
@property
def hvac_mode(self):
"""Return hvac operation ie. heat, cool mode."""
if not self.values.mode:
return None
return ZW_HVAC_MODE_MAPPINGS.get(
self.values.mode.value[VALUE_SELECTED_ID], HVAC_MODE_AUTO
)
@property
def hvac_modes(self):
"""Return the list of available hvac operation modes."""
if not self.values.mode:
return []
# Z-Wave uses one list for both modes and presets. Extract the unique modes
all_modes = []
for val in self.values.mode.value[VALUE_LIST]:
hass_mode = ZW_HVAC_MODE_MAPPINGS.get(val[VALUE_ID])
if hass_mode and hass_mode not in all_modes:
all_modes.append(hass_mode)
return all_modes
@property
def fan_mode(self):
"""Return the fan speed set."""
return self.values.fan_mode.value[VALUE_SELECTED_LABEL]
@property
def fan_modes(self):
"""Return a list of available fan modes."""
return [entry[VALUE_LABEL] for entry in self.values.fan_mode.value[VALUE_LIST]]
@property
def temperature_unit(self):
"""Return the unit of measurement."""
if self.values.temperature and self.values.temperature.units == "F":
return TEMP_FAHRENHEIT
return TEMP_CELSIUS
@property
def current_temperature(self):
"""Return the current temperature."""
if not self.values.temperature:
return None
return self.values.temperature.value
@property
def hvac_action(self):
"""Return the current running hvac operation if supported."""
if not self.values.operating_state:
return None
cur_state = self.values.operating_state.value.lower()
return HVAC_CURRENT_MAPPINGS.get(cur_state)
@property
def preset_mode(self):
"""Return preset operation ie. eco, away."""
# Z-Wave uses mode-values > 10 for presets
if self.values.mode.value[VALUE_SELECTED_ID] > 10:
return self.values.mode.value[VALUE_SELECTED_LABEL]
return PRESET_NONE
@property
def preset_modes(self):
"""Return the list of available preset operation modes."""
# Z-Wave uses mode-values > 10 for presets
return [PRESET_NONE] + [
val[VALUE_LABEL]
for val in self.values.mode.value[VALUE_LIST]
if val[VALUE_ID] > 10
]
@property
def target_temperature(self):
"""Return the temperature we try to reach."""
return self._current_mode_setpoint_values[0].value
@property
def target_temperature_low(self) -> Optional[float]:
"""Return the lowbound target temperature we try to reach."""
return self._current_mode_setpoint_values[0].value
@property
def target_temperature_high(self) -> Optional[float]:
"""Return the highbound target temperature we try to reach."""
return self._current_mode_setpoint_values[1].value
async def async_set_temperature(self, **kwargs):
"""Set new target temperature.
Must know if single or double setpoint.
"""
if len(self._current_mode_setpoint_values) == 1:
setpoint = self._current_mode_setpoint_values[0]
target_temp = kwargs.get(ATTR_TEMPERATURE)
if setpoint is not None and target_temp is not None:
setpoint.send_value(target_temp)
elif len(self._current_mode_setpoint_values) == 2:
(setpoint_low, setpoint_high) = self._current_mode_setpoint_values
target_temp_low = kwargs.get(ATTR_TARGET_TEMP_LOW)
target_temp_high = kwargs.get(ATTR_TARGET_TEMP_HIGH)
if setpoint_low is not None and target_temp_low is not None:
setpoint_low.send_value(target_temp_low)
if setpoint_high is not None and target_temp_high is not None:
setpoint_high.send_value(target_temp_high)
async def async_set_fan_mode(self, fan_mode):
"""Set new target fan mode."""
# get id for this fan_mode
fan_mode_value = _get_list_id(self.values.fan_mode.value[VALUE_LIST], fan_mode)
if fan_mode_value is None:
_LOGGER.warning("Received an invalid fan mode: %s", fan_mode)
return
self.values.fan_mode.send_value(fan_mode_value)
async def async_set_hvac_mode(self, hvac_mode):
"""Set new target hvac mode."""
if not self.values.mode:
return
if hvac_mode not in self.hvac_modes:
_LOGGER.warning("Received an invalid hvac mode: %s", hvac_mode)
return
hvac_mode_value = HVAC_MODE_ZW_MAPPINGS.get(hvac_mode)
self.values.mode.send_value(hvac_mode_value)
async def async_set_preset_mode(self, preset_mode):
"""Set new target preset mode."""
if preset_mode == PRESET_NONE:
# try to restore to the (translated) main hvac mode
await self.async_set_hvac_mode(self.hvac_mode)
return
preset_mode_value = _get_list_id(
self.values.mode.value[VALUE_LIST], preset_mode
)
if preset_mode_value is None:
_LOGGER.warning("Received an invalid preset mode: %s", preset_mode)
return
self.values.mode.send_value(preset_mode_value)
@property
def device_state_attributes(self):
"""Return the optional state attributes."""
data = super().device_state_attributes
if self.values.fan_action:
data[ATTR_FAN_ACTION] = self.values.fan_action.value
if self.values.valve_position:
data[
ATTR_VALVE_POSITION
] = f"{self.values.valve_position.value} {self.values.valve_position.units}"
return data
@property
def supported_features(self):
"""Return the list of supported features."""
support = 0
if len(self._current_mode_setpoint_values) == 1:
support |= SUPPORT_TARGET_TEMPERATURE
if len(self._current_mode_setpoint_values) > 1:
support |= SUPPORT_TARGET_TEMPERATURE_RANGE
if self.values.fan_mode:
support |= SUPPORT_FAN_MODE
if self.values.mode:
support |= SUPPORT_PRESET_MODE
return support
def _get_current_mode_setpoint_values(self) -> Tuple:
"""Return a tuple of current setpoint Z-Wave value(s)."""
current_mode = self.values.mode.value[VALUE_SELECTED_ID]
setpoint_names = MODE_SETPOINT_MAPPINGS.get(current_mode, ())
# we do not want None values in our tuple so check if the value exists
return tuple(
getattr(self.values, value_name)
for value_name in setpoint_names
if getattr(self.values, value_name, None)
)
def _get_list_id(value_lst, value_lbl):
"""Return the id for the value in the list."""
return next(
(val[VALUE_ID] for val in value_lst if val[VALUE_LABEL] == value_lbl), None
)
+8 -1
View File
@@ -1,12 +1,19 @@
"""Constants for the ozw integration."""
from homeassistant.components.binary_sensor import DOMAIN as BINARY_SENSOR_DOMAIN
from homeassistant.components.climate import DOMAIN as CLIMATE_DOMAIN
from homeassistant.components.light import DOMAIN as LIGHT_DOMAIN
from homeassistant.components.sensor import DOMAIN as SENSOR_DOMAIN
from homeassistant.components.switch import DOMAIN as SWITCH_DOMAIN
DOMAIN = "ozw"
DATA_UNSUBSCRIBE = "unsubscribe"
PLATFORMS = [BINARY_SENSOR_DOMAIN, LIGHT_DOMAIN, SENSOR_DOMAIN, SWITCH_DOMAIN]
PLATFORMS = [
BINARY_SENSOR_DOMAIN,
CLIMATE_DOMAIN,
LIGHT_DOMAIN,
SENSOR_DOMAIN,
SWITCH_DOMAIN,
]
# MQTT Topics
TOPIC_OPENZWAVE = "OpenZWave"
+101
View File
@@ -30,6 +30,107 @@ DISCOVERY_SCHEMAS = (
}
},
},
{ # Z-Wave Thermostat device translates to Climate entity
const.DISC_COMPONENT: "climate",
const.DISC_GENERIC_DEVICE_CLASS: (
const_ozw.GENERIC_TYPE_THERMOSTAT,
const_ozw.GENERIC_TYPE_SENSOR_MULTILEVEL,
),
const.DISC_SPECIFIC_DEVICE_CLASS: (
const_ozw.SPECIFIC_TYPE_THERMOSTAT_GENERAL,
const_ozw.SPECIFIC_TYPE_THERMOSTAT_GENERAL_V2,
const_ozw.SPECIFIC_TYPE_SETBACK_THERMOSTAT,
const_ozw.SPECIFIC_TYPE_THERMOSTAT_HEATING,
const_ozw.SPECIFIC_TYPE_SETPOINT_THERMOSTAT,
const_ozw.SPECIFIC_TYPE_NOT_USED,
),
const.DISC_VALUES: {
const.DISC_PRIMARY: {
const.DISC_COMMAND_CLASS: (CommandClass.THERMOSTAT_MODE,)
},
"mode": {
const.DISC_COMMAND_CLASS: (CommandClass.THERMOSTAT_MODE,),
const.DISC_OPTIONAL: True,
},
"temperature": {
const.DISC_COMMAND_CLASS: (CommandClass.SENSOR_MULTILEVEL,),
const.DISC_INDEX: (1,),
const.DISC_OPTIONAL: True,
},
"fan_mode": {
const.DISC_COMMAND_CLASS: (CommandClass.THERMOSTAT_FAN_MODE,),
const.DISC_OPTIONAL: True,
},
"operating_state": {
const.DISC_COMMAND_CLASS: (CommandClass.THERMOSTAT_OPERATING_STATE,),
const.DISC_OPTIONAL: True,
},
"fan_action": {
const.DISC_COMMAND_CLASS: (CommandClass.THERMOSTAT_FAN_STATE,),
const.DISC_OPTIONAL: True,
},
"valve_position": {
const.DISC_COMMAND_CLASS: (CommandClass.SWITCH_MULTILEVEL,),
const.DISC_INDEX: (0,),
const.DISC_OPTIONAL: True,
},
"setpoint_heating": {
const.DISC_COMMAND_CLASS: (CommandClass.THERMOSTAT_SETPOINT,),
const.DISC_INDEX: (1,),
const.DISC_OPTIONAL: True,
},
"setpoint_cooling": {
const.DISC_COMMAND_CLASS: (CommandClass.THERMOSTAT_SETPOINT,),
const.DISC_INDEX: (2,),
const.DISC_OPTIONAL: True,
},
"setpoint_furnace": {
const.DISC_COMMAND_CLASS: (CommandClass.THERMOSTAT_SETPOINT,),
const.DISC_INDEX: (7,),
const.DISC_OPTIONAL: True,
},
"setpoint_dry_air": {
const.DISC_COMMAND_CLASS: (CommandClass.THERMOSTAT_SETPOINT,),
const.DISC_INDEX: (8,),
const.DISC_OPTIONAL: True,
},
"setpoint_moist_air": {
const.DISC_COMMAND_CLASS: (CommandClass.THERMOSTAT_SETPOINT,),
const.DISC_INDEX: (9,),
const.DISC_OPTIONAL: True,
},
"setpoint_auto_changeover": {
const.DISC_COMMAND_CLASS: (CommandClass.THERMOSTAT_SETPOINT,),
const.DISC_INDEX: (10,),
const.DISC_OPTIONAL: True,
},
"setpoint_eco_heating": {
const.DISC_COMMAND_CLASS: (CommandClass.THERMOSTAT_SETPOINT,),
const.DISC_INDEX: (11,),
const.DISC_OPTIONAL: True,
},
"setpoint_eco_cooling": {
const.DISC_COMMAND_CLASS: (CommandClass.THERMOSTAT_SETPOINT,),
const.DISC_INDEX: (12,),
const.DISC_OPTIONAL: True,
},
"setpoint_away_heating": {
const.DISC_COMMAND_CLASS: (CommandClass.THERMOSTAT_SETPOINT,),
const.DISC_INDEX: (13,),
const.DISC_OPTIONAL: True,
},
"setpoint_away_cooling": {
const.DISC_COMMAND_CLASS: (CommandClass.THERMOSTAT_SETPOINT,),
const.DISC_INDEX: (14,),
const.DISC_OPTIONAL: True,
},
"setpoint_full_power": {
const.DISC_COMMAND_CLASS: (CommandClass.THERMOSTAT_SETPOINT,),
const.DISC_INDEX: (15,),
const.DISC_OPTIONAL: True,
},
},
},
{ # Light
const.DISC_COMPONENT: "light",
const.DISC_GENERIC_DEVICE_CLASS: (
+17
View File
@@ -21,6 +21,12 @@ def light_data_fixture():
return load_fixture("ozw/light_network_dump.csv")
@pytest.fixture(name="climate_data", scope="session")
def climate_data_fixture():
"""Load climate MQTT data and return it."""
return load_fixture("ozw/climate_network_dump.csv")
@pytest.fixture(name="sent_messages")
def sent_messages_fixture():
"""Fixture to capture sent messages."""
@@ -88,3 +94,14 @@ async def binary_sensor_alt_msg_fixture(hass):
message = MQTTMessage(topic=sensor_json["topic"], payload=sensor_json["payload"])
message.encode()
return message
@pytest.fixture(name="climate_msg")
async def climate_msg_fixture(hass):
"""Return a mock MQTT msg with a climate mode change message."""
sensor_json = json.loads(
await hass.async_add_executor_job(load_fixture, "ozw/climate.json")
)
message = MQTTMessage(topic=sensor_json["topic"], payload=sensor_json["payload"])
message.encode()
return message
+220
View File
@@ -0,0 +1,220 @@
"""Test Z-Wave Multi-setpoint Climate entities."""
from homeassistant.components.climate import ATTR_TEMPERATURE
from homeassistant.components.climate.const import (
ATTR_CURRENT_TEMPERATURE,
ATTR_FAN_MODE,
ATTR_FAN_MODES,
ATTR_HVAC_ACTION,
ATTR_HVAC_MODES,
ATTR_PRESET_MODES,
ATTR_TARGET_TEMP_HIGH,
ATTR_TARGET_TEMP_LOW,
CURRENT_HVAC_IDLE,
HVAC_MODE_AUTO,
HVAC_MODE_COOL,
HVAC_MODE_HEAT,
HVAC_MODE_OFF,
)
from .common import setup_ozw
async def test_climate(hass, climate_data, sent_messages, climate_msg, caplog):
"""Test setting up config entry."""
receive_message = await setup_ozw(hass, fixture=climate_data)
# Test multi-setpoint thermostat (node 7 in dump)
# mode is heat, this should be single setpoint
state = hass.states.get("climate.ct32_thermostat_mode")
assert state is not None
assert state.state == HVAC_MODE_HEAT
assert state.attributes[ATTR_HVAC_MODES] == [
HVAC_MODE_OFF,
HVAC_MODE_HEAT,
HVAC_MODE_COOL,
HVAC_MODE_AUTO,
]
assert state.attributes[ATTR_HVAC_ACTION] == CURRENT_HVAC_IDLE
assert state.attributes[ATTR_CURRENT_TEMPERATURE] == 23.1
assert state.attributes[ATTR_TEMPERATURE] == 21.1
assert state.attributes.get(ATTR_TARGET_TEMP_LOW) is None
assert state.attributes.get(ATTR_TARGET_TEMP_HIGH) is None
assert state.attributes[ATTR_FAN_MODE] == "Auto Low"
assert state.attributes[ATTR_FAN_MODES] == ["Auto Low", "On Low"]
# Test set target temperature
await hass.services.async_call(
"climate",
"set_temperature",
{"entity_id": "climate.ct32_thermostat_mode", "temperature": 26.1},
blocking=True,
)
assert len(sent_messages) == 1
msg = sent_messages[-1]
assert msg["topic"] == "OpenZWave/1/command/setvalue/"
# Celsius is converted to Fahrenheit here!
assert round(msg["payload"]["Value"], 2) == 78.98
assert msg["payload"]["ValueIDKey"] == 281475099443218
# Test set mode
await hass.services.async_call(
"climate",
"set_hvac_mode",
{"entity_id": "climate.ct32_thermostat_mode", "hvac_mode": HVAC_MODE_AUTO},
blocking=True,
)
assert len(sent_messages) == 2
msg = sent_messages[-1]
assert msg["topic"] == "OpenZWave/1/command/setvalue/"
assert msg["payload"] == {"Value": 3, "ValueIDKey": 122683412}
# Test set missing mode
await hass.services.async_call(
"climate",
"set_hvac_mode",
{"entity_id": "climate.ct32_thermostat_mode", "hvac_mode": "fan_only"},
blocking=True,
)
assert len(sent_messages) == 2
assert "Received an invalid hvac mode: fan_only" in caplog.text
# Test set fan mode
await hass.services.async_call(
"climate",
"set_fan_mode",
{"entity_id": "climate.ct32_thermostat_mode", "fan_mode": "On Low"},
blocking=True,
)
assert len(sent_messages) == 3
msg = sent_messages[-1]
assert msg["topic"] == "OpenZWave/1/command/setvalue/"
assert msg["payload"] == {"Value": 1, "ValueIDKey": 122748948}
# Test set invalid fan mode
await hass.services.async_call(
"climate",
"set_fan_mode",
{"entity_id": "climate.ct32_thermostat_mode", "fan_mode": "invalid fan mode"},
blocking=True,
)
assert len(sent_messages) == 3
assert "Received an invalid fan mode: invalid fan mode" in caplog.text
# Test incoming mode change to auto,
# resulting in multiple setpoints
receive_message(climate_msg)
await hass.async_block_till_done()
state = hass.states.get("climate.ct32_thermostat_mode")
assert state is not None
assert state.state == HVAC_MODE_AUTO
assert state.attributes.get(ATTR_TEMPERATURE) is None
assert state.attributes[ATTR_TARGET_TEMP_LOW] == 21.1
assert state.attributes[ATTR_TARGET_TEMP_HIGH] == 25.6
# Test setting high/low temp on multiple setpoints
await hass.services.async_call(
"climate",
"set_temperature",
{
"entity_id": "climate.ct32_thermostat_mode",
"target_temp_low": 20,
"target_temp_high": 25,
},
blocking=True,
)
assert len(sent_messages) == 5 # 2 messages !
msg = sent_messages[-2] # low setpoint
assert msg["topic"] == "OpenZWave/1/command/setvalue/"
assert round(msg["payload"]["Value"], 2) == 68.0
assert msg["payload"]["ValueIDKey"] == 281475099443218
msg = sent_messages[-1] # high setpoint
assert msg["topic"] == "OpenZWave/1/command/setvalue/"
assert round(msg["payload"]["Value"], 2) == 77.0
assert msg["payload"]["ValueIDKey"] == 562950076153874
# Test basic/single-setpoint thermostat (node 16 in dump)
state = hass.states.get("climate.komforthaus_spirit_z_wave_plus_mode")
assert state is not None
assert state.state == HVAC_MODE_HEAT
assert state.attributes[ATTR_HVAC_MODES] == [
HVAC_MODE_OFF,
HVAC_MODE_HEAT,
]
assert state.attributes[ATTR_CURRENT_TEMPERATURE] == 17.3
assert round(state.attributes[ATTR_TEMPERATURE], 0) == 19
assert state.attributes.get(ATTR_TARGET_TEMP_LOW) is None
assert state.attributes.get(ATTR_TARGET_TEMP_HIGH) is None
assert state.attributes[ATTR_PRESET_MODES] == [
"none",
"Heat Eco",
"Full Power",
"Manufacturer Specific",
]
# Test set target temperature
await hass.services.async_call(
"climate",
"set_temperature",
{
"entity_id": "climate.komforthaus_spirit_z_wave_plus_mode",
"temperature": 28.0,
},
blocking=True,
)
assert len(sent_messages) == 6
msg = sent_messages[-1]
assert msg["topic"] == "OpenZWave/1/command/setvalue/"
assert msg["payload"] == {
"Value": 28.0,
"ValueIDKey": 281475250438162,
}
# Test set preset mode
await hass.services.async_call(
"climate",
"set_preset_mode",
{
"entity_id": "climate.komforthaus_spirit_z_wave_plus_mode",
"preset_mode": "Heat Eco",
},
blocking=True,
)
assert len(sent_messages) == 7
msg = sent_messages[-1]
assert msg["topic"] == "OpenZWave/1/command/setvalue/"
assert msg["payload"] == {
"Value": 11,
"ValueIDKey": 273678356,
}
# Test set preset mode None
# This preset should set and return to current hvac mode
await hass.services.async_call(
"climate",
"set_preset_mode",
{
"entity_id": "climate.komforthaus_spirit_z_wave_plus_mode",
"preset_mode": "none",
},
blocking=True,
)
assert len(sent_messages) == 8
msg = sent_messages[-1]
assert msg["topic"] == "OpenZWave/1/command/setvalue/"
assert msg["payload"] == {
"Value": 1,
"ValueIDKey": 273678356,
}
# Test set invalid preset mode
await hass.services.async_call(
"climate",
"set_preset_mode",
{
"entity_id": "climate.komforthaus_spirit_z_wave_plus_mode",
"preset_mode": "invalid preset mode",
},
blocking=True,
)
assert len(sent_messages) == 8
assert "Received an invalid preset mode: invalid preset mode" in caplog.text
+54
View File
@@ -0,0 +1,54 @@
{
"topic": "OpenZWave/1/node/7/instance/1/commandclass/64/value/122683412/",
"payload": {
"Label": "Mode",
"Value": {
"List": [
{
"Value": 0,
"Label": "Off"
},
{
"Value": 1,
"Label": "Heat"
},
{
"Value": 2,
"Label": "Cool"
},
{
"Value": 3,
"Label": "Auto"
},
{
"Value": 11,
"Label": "Heat Econ"
},
{
"Value": 12,
"Label": "Cool Econ"
}
],
"Selected": "Auto",
"Selected_id": 3
},
"Units": "",
"Min": 0,
"Max": 0,
"Type": "List",
"Instance": 1,
"CommandClass": "COMMAND_CLASS_THERMOSTAT_MODE",
"Index": 0,
"Node": 7,
"Genre": "User",
"Help": "Set the Thermostat Mode",
"ValueIDKey": 122683412,
"ReadOnly": false,
"WriteOnly": false,
"ValueSet": false,
"ValuePolled": false,
"ChangeVerified": false,
"Event": "valueAdded",
"TimeStamp": 1588264894
}
}
+140
View File
@@ -0,0 +1,140 @@
OpenZWave/1/status/,{ "OpenZWave_Version": "1.6.1008", "OZWDeamon_Version": "0.1", "QTOpenZWave_Version": "1.0.0", "QT_Version": "5.12.5", "Status": "driverAllNodesQueried", "TimeStamp": 1579566933, "ManufacturerSpecificDBReady": true, "homeID": 3245146787, "getControllerNodeId": 1, "getSUCNodeId": 1, "isPrimaryController": true, "isBridgeController": false, "hasExtendedTXStatistics": true, "getControllerLibraryVersion": "Z-Wave 3.95", "getControllerLibraryType": "Static Controller", "getControllerPath": "/dev/zwave"}
OpenZWave/1/node/7/,{ "NodeID": 7, "NodeQueryStage": "Complete", "isListening": true, "isFlirs": false, "isBeaming": false, "isRouting": false, "isSecurityv1": false, "isZWavePlus": true, "isNIFRecieved": true, "isAwake": true, "isFailed": false, "MetaData": { "OZWInfoURL": "", "ZWAProductURL": "", "ProductPic": "", "Description": "", "ProductManualURL": "", "ProductPageURL": "", "InclusionHelp": "", "ExclusionHelp": "", "ResetHelp": "", "WakeupHelp": "", "ProductSupportURL": "", "Frequency": "", "Name": "", "ProductPicBase64": "" }, "Event": "nodeQueriesComplete", "TimeStamp": 1588264908, "NodeManufacturerName": "2GIG Technologies", "NodeProductName": "CT32 Thermostat", "NodeBasicString": "Routing Slave", "NodeBasic": 4, "NodeGenericString": "Thermostat", "NodeGeneric": 8, "NodeSpecificString": "General Thermostat V2", "NodeSpecific": 6, "NodeManufacturerID": "0x0098", "NodeProductType": "0x2002", "NodeProductID": "0x0100", "NodeBaudRate": 100000, "NodeVersion": 4, "NodeName": "", "NodeLocation": "", "NodeDeviceTypeString": "Thermostat HVAC", "NodeDeviceType": 4608, "NodeRole": 7, "NodeRoleString": "Listening Sleeping Slave", "NodePlusType": 0, "NodePlusTypeString": "Z-Wave+ node", "Neighbors": [ 1, 2 ]}
OpenZWave/1/node/7/instance/1/,{ "Instance": 1, "TimeStamp": 1588264894}
OpenZWave/1/node/7/instance/1/commandclass/112/,{ "Instance": 1, "CommandClassId": 112, "CommandClass": "COMMAND_CLASS_CONFIGURATION", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/112/value/281475104374804/,{ "Label": "Temperature Reporting Threshold", "Value": { "List": [ { "Value": 0, "Label": "Disabled" }, { "Value": 1, "Label": "0.5F" }, { "Value": 2, "Label": "1.0F" }, { "Value": 3, "Label": "1.5F" }, { "Value": 4, "Label": "2.0F" } ], "Selected": "1.0F", "Selected_id": 2 }, "Units": "", "Min": 0, "Max": 4, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_CONFIGURATION", "Index": 1, "Node": 7, "Genre": "Config", "Help": "The Temperature Reporting Threshold Configuration Set Command sets the reporting threshold for changes in the ambient temperature as detected by the thermostat.", "ValueIDKey": 281475104374804, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/112/value/562950081085460/,{ "Label": "HVAC Settings", "Value": { "List": [ { "Value": 17891585, "Label": "HVAC: Normal, Aux Stages: 1, Aux Setup: Gas, Heat Pump Stages: 1, Cool Stages: 1" }, { "Value": 34668801, "Label": "HVAC: Heat Pump, Aux Stages: 1, Aux Setup: Gas, Heat Pump Stages: 1, Cool Stages: 1" }, { "Value": 18940161, "Label": "HVAC: Normal, Aux Stages: 2, Aux Setup: Gas, Heat Pump Stages: 1, Cool Stages: 1" }, { "Value": 35717377, "Label": "HVAC: Heat Pump, Aux Stages: 2, Aux Setup: Gas, Heat Pump Stages: 1, Cool Stages: 1" }, { "Value": 17957121, "Label": "HVAC: Normal, Aux Stages: 1, Aux Setup: Elec, Heat Pump Stages: 1, Cool Stages: 1" }, { "Value": 34734337, "Label": "HVAC: Heat Pump, Aux Stages: 1, Aux Setup: Elec, Heat Pump Stages: 1, Cool Stages: 1" }, { "Value": 19005697, "Label": "HVAC: Normal, Aux Stages: 2, Aux Setup: Elec, Heat Pump Stages: 1, Cool Stages: 1" }, { "Value": 35782913, "Label": "HVAC: Heat Pump, Aux Stages: 2, Aux Setup: Elec, Heat Pump Stages: 1, Cool Stages: 1" }, { "Value": 17891841, "Label": "HVAC: Normal, Aux Stages: 1, Aux Setup: Gas, Heat Pump Stages: 2, Cool Stages: 1" }, { "Value": 34669057, "Label": "HVAC: Heat Pump, Aux Stages: 1, Aux Setup: Gas, Heat Pump Stages: 2, Cool Stages: 1" }, { "Value": 18940417, "Label": "HVAC: Normal, Aux Stages: 2, Aux Setup: Gas, Heat Pump Stages: 2, Cool Stages: 1" }, { "Value": 35717633, "Label": "HVAC: Heat Pump, Aux Stages: 2, Aux Setup: Gas, Heat Pump Stages: 2, Cool Stages: 1" }, { "Value": 17957377, "Label": "HVAC: Normal, Aux Stages: 1, Aux Setup: Elec, Heat Pump Stages: 2, Cool Stages: 1" }, { "Value": 34734593, "Label": "HVAC: Heat Pump, Aux Stages: 1, Aux Setup: Elec, Heat Pump Stages: 2, Cool Stages: 1" }, { "Value": 19005953, "Label": "HVAC: Normal, Aux Stages: 2, Aux Setup: Elec, Heat Pump Stages: 2, Cool Stages: 1" }, { "Value": 35783169, "Label": "HVAC: Heat Pump, Aux Stages: 2, Aux Setup: Elec, Heat Pump Stages: 2, Cool Stages: 1" }, { "Value": 17891586, "Label": "HVAC: Normal, Aux Stages: 1, Aux Setup: Gas, Heat Pump Stages: 1, Cool Stages: 2" }, { "Value": 34668802, "Label": "HVAC: Heat Pump, Aux Stages: 1, Aux Setup: Gas, Heat Pump Stages: 1, Cool Stages: 2" }, { "Value": 18940162, "Label": "HVAC: Normal, Aux Stages: 2, Aux Setup: Gas, Heat Pump Stages: 1, Cool Stages: 2" }, { "Value": 35717378, "Label": "HVAC: Heat Pump, Aux Stages: 2, Aux Setup: Gas, Heat Pump Stages: 1, Cool Stages: 2" }, { "Value": 17957122, "Label": "HVAC: Normal, Aux Stages: 1, Aux Setup: Elec, Heat Pump Stages: 1, Cool Stages: 2" }, { "Value": 34734338, "Label": "HVAC: Heat Pump, Aux Stages: 1, Aux Setup: Elec, Heat Pump Stages: 1, Cool Stages: 2" }, { "Value": 19005698, "Label": "HVAC: Normal, Aux Stages: 2, Aux Setup: Elec, Heat Pump Stages: 1, Cool Stages: 2" }, { "Value": 35782914, "Label": "HVAC: Heat Pump, Aux Stages: 2, Aux Setup: Elec, Heat Pump Stages: 1, Cool Stages: 2" }, { "Value": 17891842, "Label": "HVAC: Normal, Aux Stages: 1, Aux Setup: Gas, Heat Pump Stages: 2, Cool Stages: 2" }, { "Value": 34669058, "Label": "HVAC: Heat Pump, Aux Stages: 1, Aux Setup: Gas, Heat Pump Stages: 2, Cool Stages: 2" }, { "Value": 18940418, "Label": "HVAC: Normal, Aux Stages: 2, Aux Setup: Gas, Heat Pump Stages: 2, Cool Stages: 2" }, { "Value": 35717634, "Label": "HVAC: Heat Pump, Aux Stages: 2, Aux Setup: Gas, Heat Pump Stages: 2, Cool Stages: 2" }, { "Value": 17957378, "Label": "HVAC: Normal, Aux Stages: 1, Aux SetuLine truncated
OpenZWave/1/node/7/instance/1/commandclass/112/value/844425057796116/,{ "Label": "Utility Lock", "Value": { "List": [ { "Value": 0, "Label": "Disable" }, { "Value": 1, "Label": "Enable" } ], "Selected": "Disable", "Selected_id": 0 }, "Units": "", "Min": 0, "Max": 1, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_CONFIGURATION", "Index": 3, "Node": 7, "Genre": "Config", "Help": "The Utility Lock Configuration Set command enables or disables the utility lock. If the utility lock is enabled, the setpoint cannot be modified directly via the thermostat screen.", "ValueIDKey": 844425057796116, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/112/value/1125900034506772/,{ "Label": "C-Wire/Battery Status", "Value": { "List": [ { "Value": 1, "Label": "C-Wire" }, { "Value": 2, "Label": "Battery" } ], "Selected": "C-Wire", "Selected_id": 1 }, "Units": "", "Min": 1, "Max": 2, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_CONFIGURATION", "Index": 4, "Node": 7, "Genre": "Config", "Help": "1 -> C-Wire 2 -> Battery", "ValueIDKey": 1125900034506772, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/112/value/1407375011217428/,{ "Label": "Humidity Reporting Threshold", "Value": { "List": [ { "Value": 0, "Label": "Disabled" }, { "Value": 1, "Label": "3% RH" }, { "Value": 2, "Label": "5% RH" }, { "Value": 3, "Label": "10% RH" } ], "Selected": "5% RH", "Selected_id": 2 }, "Units": "", "Min": 0, "Max": 3, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_CONFIGURATION", "Index": 5, "Node": 7, "Genre": "Config", "Help": "The Humidity Reporting Threshold Configuration Set Command sets the reporting threshold for changes in the ambient humidity as detected by the thermostat.", "ValueIDKey": 1407375011217428, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/112/value/1688849987928084/,{ "Label": "Auxiliary/Emergency heat", "Value": { "List": [ { "Value": 0, "Label": "Disabled" }, { "Value": 1, "Label": "Enabled" } ], "Selected": "Disabled", "Selected_id": 0 }, "Units": "", "Min": 0, "Max": 1, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_CONFIGURATION", "Index": 6, "Node": 7, "Genre": "Config", "Help": "The Auxiliary/Emergency configuration command enables or disables auxiliary / emergency heating in the thermostat. Auxiliary / emergency heating is only available if the thermostat is configured in heat pump mode and with at least one stage of auxiliary heating. This command enables auxiliary / emergency heating when the thermostat is in Auto mode. The Thermostat Set Mode command with mode Auxiliary/Emergency Heat will enable emergency heating but only if the thermostat is in Heat mode. This command should only be used on thermsotats that support Auxiliary/Emergency Heat thermostat mode.", "ValueIDKey": 1688849987928084, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/112/value/1970324964638740/,{ "Label": "Thermostat Swing Temperature", "Value": { "List": [ { "Value": 1, "Label": "0.5F" }, { "Value": 2, "Label": "1.0F" }, { "Value": 3, "Label": "1.5F" }, { "Value": 4, "Label": "2.0F" }, { "Value": 5, "Label": "2.5F" }, { "Value": 6, "Label": "3.0F" }, { "Value": 7, "Label": "3.5F" }, { "Value": 8, "Label": "4.0F" } ], "Selected": "1.0F", "Selected_id": 2 }, "Units": "", "Min": 1, "Max": 8, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_CONFIGURATION", "Index": 7, "Node": 7, "Genre": "Config", "Help": "The Temperate Swing (HVAC cycling rate) is the desired variance in temperature between the thermostat setting and the room temperature required before the heating or cooling system will turn on.", "ValueIDKey": 1970324964638740, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/112/value/2251799941349396/,{ "Label": "Thermostat Differential Temperature", "Value": { "List": [ { "Value": 4, "Label": "2.0F Heat" }, { "Value": 6, "Label": "3.0F Heat" }, { "Value": 8, "Label": "4.0F Heat" }, { "Value": 10, "Label": "5.0F Heat" }, { "Value": 12, "Label": "6.0F Heat" }, { "Value": 260, "Label": "2.0F Cool" }, { "Value": 262, "Label": "3.0F Cool" }, { "Value": 264, "Label": "4.0F Cool" }, { "Value": 266, "Label": "5.0F Cool" }, { "Value": 268, "Label": "6.0F Cool" } ], "Selected": "2.0F Heat", "Selected_id": 4 }, "Units": "F", "Min": 2, "Max": 32767, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_CONFIGURATION", "Index": 8, "Node": 7, "Genre": "Config", "Help": "(Set Only) The Thermostat Differential Temperature configuration command sets the differential temperature for multi-stage HVAC systems. The differential temperature delta defines when the thermostat will turn on additional stages. There are two differential temperatures, one for multistage cool systems and one for multistage heat systems. If the thermostat is not configured for multistage HVAC systems then these parameters have no effect.", "ValueIDKey": 2251799941349396, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/112/value/2533274918060052/,{ "Label": "Thermostat Recovery Mode", "Value": { "List": [ { "Value": 1, "Label": "Fast" }, { "Value": 2, "Label": "Economy" } ], "Selected": "Economy", "Selected_id": 2 }, "Units": "", "Min": 1, "Max": 2, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_CONFIGURATION", "Index": 9, "Node": 7, "Genre": "Config", "Help": "The Thermostat Recovery Mode configuration command sets the HVAC recovery mode type. The recovery mode determines when additional HVAC stages are turned off as the ambient temperature returns to the target temperature. If the recovery mode is set to economy, the thermostat will turn off additional HVAC stages when the ambient temperature reaches the target temperature plus/minus the differential temperature. If the recovery mode is set to fast, the thermostat will leave all stages on (assuming they were already on) until the ambient temperature reaches the target temperature.", "ValueIDKey": 2533274918060052, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/112/value/2814749894770710/,{ "Label": "Temperature Reporting Filter", "Value": 124, "Units": "F", "Min": 0, "Max": 124, "Type": "Short", "Instance": 1, "CommandClass": "COMMAND_CLASS_CONFIGURATION", "Index": 10, "Node": 7, "Genre": "Config", "Help": "The Temperature Reporting Filter configuration command sets upper and lower bounds of the ambient temperature reporting. The thermostat won't report ambient temperature changes if the ambient temperature falls between these bounds. For example, if the upper bound is 80F and the lower bound is 60F, the thermostat will not send SENSOR_MULTI_LEVEL_REPORTS for ambient temperature values between 60F and 80F. The thermostat will only send ambient temperature changes if the thermostat has been added to an association group (see Command Class Association) and the temperature reporting threshold is non-zero (see Temperature Reporting Threshold). Input in hexadecimal only like so: 0x09 0x05 0x09 0x0A. It must always have four 1 byte sized numbers. The first two bytes control the lower temperature bound for the Temperature Reporting Filter the last two control the upper temperature bound. The first byte in the byte pair always refers to temperature scale (Celsius 0x01 or Fahrenheit 0x09). While the second byte in each byte pair is the bound temperature. The max/min temp you can use is 127 degrees. To convert decimal to hex goto: https://www.binaryhexconverter.com/decimal-to-hex-converter or you can use the built in Windows calculator program in Programmer mode. If you mess up your thermostat copy and paste 0x09 0x00 0x09 0x00 (for a F Thermostat) or 0x01 0x00 0x01 0x00 (for a C Thermostat). This will remove any bounds.", "ValueIDKey": 2814749894770710, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/112/value/3096224871481364/,{ "Label": "Simple UI Mode", "Value": { "List": [ { "Value": 0, "Label": "Enable" }, { "Value": 1, "Label": "Disable" } ], "Selected": "Disable", "Selected_id": 1 }, "Units": "", "Min": 0, "Max": 1, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_CONFIGURATION", "Index": 11, "Node": 7, "Genre": "Config", "Help": "If the value is set to Disable then Normal Mode is enabled. If the value is set to Enable then Simple Mode is enabled.", "ValueIDKey": 3096224871481364, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/112/value/3377699848192017/,{ "Label": "Multicast", "Value": 0, "Units": "", "Min": 0, "Max": 1, "Type": "Byte", "Instance": 1, "CommandClass": "COMMAND_CLASS_CONFIGURATION", "Index": 12, "Node": 7, "Genre": "Config", "Help": "If set to 0, multicast is disabled, if set to 1, will enable the multicast.", "ValueIDKey": 3377699848192017, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/66/,{ "Instance": 1, "CommandClassId": 66, "CommandClass": "COMMAND_CLASS_THERMOSTAT_OPERATING_STATE", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/66/value/122716183/,{ "Label": "Operating State", "Value": "Idle", "Units": "", "Min": 0, "Max": 0, "Type": "String", "Instance": 1, "CommandClass": "COMMAND_CLASS_THERMOSTAT_OPERATING_STATE", "Index": 0, "Node": 7, "Genre": "User", "Help": "Set the Thermostat Operating State", "ValueIDKey": 122716183, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/69/,{ "Instance": 1, "CommandClassId": 69, "CommandClass": "COMMAND_CLASS_THERMOSTAT_FAN_STATE", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/69/value/122765335/,{ "Label": "Fan State", "Value": "Idle", "Units": "", "Min": 0, "Max": 0, "Type": "String", "Instance": 1, "CommandClass": "COMMAND_CLASS_THERMOSTAT_FAN_STATE", "Index": 0, "Node": 7, "Genre": "User", "Help": "Set the Fan State", "ValueIDKey": 122765335, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/94/,{ "Instance": 1, "CommandClassId": 94, "CommandClass": "COMMAND_CLASS_ZWAVEPLUS_INFO", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/94/value/131563537/,{ "Label": "ZWave+ Version", "Value": 1, "Units": "", "Min": 0, "Max": 255, "Type": "Byte", "Instance": 1, "CommandClass": "COMMAND_CLASS_ZWAVEPLUS_INFO", "Index": 0, "Node": 7, "Genre": "System", "Help": "ZWave+ Version Supported on the Device", "ValueIDKey": 131563537, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueChanged", "TimeStamp": 1588264894}
OpenZWave/1/node/7/instance/1/commandclass/94/value/281475108274198/,{ "Label": "InstallerIcon", "Value": 4608, "Units": "", "Min": -32768, "Max": 32767, "Type": "Short", "Instance": 1, "CommandClass": "COMMAND_CLASS_ZWAVEPLUS_INFO", "Index": 1, "Node": 7, "Genre": "System", "Help": "Icon File to use for the Installer Application", "ValueIDKey": 281475108274198, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueChanged", "TimeStamp": 1588264894}
OpenZWave/1/node/7/instance/1/commandclass/94/value/562950084984854/,{ "Label": "UserIcon", "Value": 4608, "Units": "", "Min": -32768, "Max": 32767, "Type": "Short", "Instance": 1, "CommandClass": "COMMAND_CLASS_ZWAVEPLUS_INFO", "Index": 2, "Node": 7, "Genre": "System", "Help": "Icon File to use for the User Application", "ValueIDKey": 562950084984854, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueChanged", "TimeStamp": 1588264894}
OpenZWave/1/node/7/instance/1/commandclass/114/,{ "Instance": 1, "CommandClassId": 114, "CommandClass": "COMMAND_CLASS_MANUFACTURER_SPECIFIC", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/114/value/131891219/,{ "Label": "Loaded Config Revision", "Value": 0, "Units": "", "Min": -2147483648, "Max": 2147483647, "Type": "Int", "Instance": 1, "CommandClass": "COMMAND_CLASS_MANUFACTURER_SPECIFIC", "Index": 0, "Node": 7, "Genre": "System", "Help": "Revision of the Config file currently loaded", "ValueIDKey": 131891219, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/114/value/281475108601875/,{ "Label": "Config File Revision", "Value": 6, "Units": "", "Min": -2147483648, "Max": 2147483647, "Type": "Int", "Instance": 1, "CommandClass": "COMMAND_CLASS_MANUFACTURER_SPECIFIC", "Index": 1, "Node": 7, "Genre": "System", "Help": "Revision of the Config file on the File System", "ValueIDKey": 281475108601875, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/114/value/562950085312531/,{ "Label": "Latest Available Config File Revision", "Value": 6, "Units": "", "Min": -2147483648, "Max": 2147483647, "Type": "Int", "Instance": 1, "CommandClass": "COMMAND_CLASS_MANUFACTURER_SPECIFIC", "Index": 2, "Node": 7, "Genre": "System", "Help": "Latest Revision of the Config file available for download", "ValueIDKey": 562950085312531, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/114/value/844425062023191/,{ "Label": "Device ID", "Value": "", "Units": "", "Min": 0, "Max": 0, "Type": "String", "Instance": 1, "CommandClass": "COMMAND_CLASS_MANUFACTURER_SPECIFIC", "Index": 3, "Node": 7, "Genre": "System", "Help": "Manufacturer Specific Device ID/Model", "ValueIDKey": 844425062023191, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/114/value/1125900038733847/,{ "Label": "Serial Number", "Value": "", "Units": "", "Min": 0, "Max": 0, "Type": "String", "Instance": 1, "CommandClass": "COMMAND_CLASS_MANUFACTURER_SPECIFIC", "Index": 4, "Node": 7, "Genre": "System", "Help": "Device Serial Number", "ValueIDKey": 1125900038733847, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/115/,{ "Instance": 1, "CommandClassId": 115, "CommandClass": "COMMAND_CLASS_POWERLEVEL", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/115/value/131907604/,{ "Label": "Powerlevel", "Value": { "List": [ { "Value": 0, "Label": "Normal" }, { "Value": 1, "Label": "-1dB" }, { "Value": 2, "Label": "-2dB" }, { "Value": 3, "Label": "-3dB" }, { "Value": 4, "Label": "-4dB" }, { "Value": 5, "Label": "-5dB" }, { "Value": 6, "Label": "-6dB" }, { "Value": 7, "Label": "-7dB" }, { "Value": 8, "Label": "-8dB" }, { "Value": 9, "Label": "-9dB" } ], "Selected": "Normal", "Selected_id": 0 }, "Units": "dB", "Min": 0, "Max": 0, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_POWERLEVEL", "Index": 0, "Node": 7, "Genre": "System", "Help": "Output RF PowerLevel", "ValueIDKey": 131907604, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/115/value/281475108618257/,{ "Label": "Timeout", "Value": 0, "Units": "seconds", "Min": 0, "Max": 255, "Type": "Byte", "Instance": 1, "CommandClass": "COMMAND_CLASS_POWERLEVEL", "Index": 1, "Node": 7, "Genre": "System", "Help": "Timeout till the PowerLevel is reset to Normal", "ValueIDKey": 281475108618257, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/115/value/562950085328920/,{ "Label": "Set Powerlevel", "Value": false, "Units": "", "Min": 0, "Max": 0, "Type": "Button", "Instance": 1, "CommandClass": "COMMAND_CLASS_POWERLEVEL", "Index": 2, "Node": 7, "Genre": "System", "Help": "Apply the Output PowerLevel and Timeout Values", "ValueIDKey": 562950085328920, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/115/value/844425062039569/,{ "Label": "Test Node", "Value": 0, "Units": "", "Min": 0, "Max": 255, "Type": "Byte", "Instance": 1, "CommandClass": "COMMAND_CLASS_POWERLEVEL", "Index": 3, "Node": 7, "Genre": "System", "Help": "Node to Perform a test against", "ValueIDKey": 844425062039569, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/115/value/1125900038750228/,{ "Label": "Test Powerlevel", "Value": { "List": [ { "Value": 0, "Label": "Normal" }, { "Value": 1, "Label": "-1dB" }, { "Value": 2, "Label": "-2dB" }, { "Value": 3, "Label": "-3dB" }, { "Value": 4, "Label": "-4dB" }, { "Value": 5, "Label": "-5dB" }, { "Value": 6, "Label": "-6dB" }, { "Value": 7, "Label": "-7dB" }, { "Value": 8, "Label": "-8dB" }, { "Value": 9, "Label": "-9dB" } ], "Selected": "Normal", "Selected_id": 0 }, "Units": "dB", "Min": 0, "Max": 0, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_POWERLEVEL", "Index": 4, "Node": 7, "Genre": "System", "Help": "PowerLevel to use for the Test", "ValueIDKey": 1125900038750228, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/115/value/1407375015460886/,{ "Label": "Frame Count", "Value": 0, "Units": "", "Min": -32768, "Max": 32767, "Type": "Short", "Instance": 1, "CommandClass": "COMMAND_CLASS_POWERLEVEL", "Index": 5, "Node": 7, "Genre": "System", "Help": "How Many Messages to send to the Node for the Test", "ValueIDKey": 1407375015460886, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/115/value/1688849992171544/,{ "Label": "Test", "Value": false, "Units": "", "Min": 0, "Max": 0, "Type": "Button", "Instance": 1, "CommandClass": "COMMAND_CLASS_POWERLEVEL", "Index": 6, "Node": 7, "Genre": "System", "Help": "Perform a PowerLevel Test against the a Node", "ValueIDKey": 1688849992171544, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/115/value/1970324968882200/,{ "Label": "Report", "Value": false, "Units": "", "Min": 0, "Max": 0, "Type": "Button", "Instance": 1, "CommandClass": "COMMAND_CLASS_POWERLEVEL", "Index": 7, "Node": 7, "Genre": "System", "Help": "Get the results of the latest PowerLevel Test against a Node", "ValueIDKey": 1970324968882200, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/115/value/2251799945592852/,{ "Label": "Test Status", "Value": { "List": [ { "Value": 0, "Label": "Failed" }, { "Value": 1, "Label": "Success" }, { "Value": 2, "Label": "In Progress" } ], "Selected": "Failed", "Selected_id": 0 }, "Units": "", "Min": 0, "Max": 0, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_POWERLEVEL", "Index": 8, "Node": 7, "Genre": "System", "Help": "The Current Status of the last PowerNode Test Executed", "ValueIDKey": 2251799945592852, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/115/value/2533274922303510/,{ "Label": "Acked Frames", "Value": 0, "Units": "", "Min": -32768, "Max": 32767, "Type": "Short", "Instance": 1, "CommandClass": "COMMAND_CLASS_POWERLEVEL", "Index": 9, "Node": 7, "Genre": "System", "Help": "Number of Messages successfully Acked by the Target Node", "ValueIDKey": 2533274922303510, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/128/,{ "Instance": 1, "CommandClassId": 128, "CommandClass": "COMMAND_CLASS_BATTERY", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/128/value/123731985/,{ "Label": "Battery Level", "Value": 65, "Units": "%", "Min": 0, "Max": 255, "Type": "Byte", "Instance": 1, "CommandClass": "COMMAND_CLASS_BATTERY", "Index": 0, "Node": 7, "Genre": "User", "Help": "Current Battery Level", "ValueIDKey": 123731985, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueChanged", "TimeStamp": 1588264908}
OpenZWave/1/node/7/instance/1/commandclass/129/,{ "Instance": 1, "CommandClassId": 129, "CommandClass": "COMMAND_CLASS_CLOCK", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/129/value/123748372/,{ "Label": "Day", "Value": { "List": [ { "Value": 1, "Label": "Monday" }, { "Value": 2, "Label": "Tuesday" }, { "Value": 3, "Label": "Wednesday" }, { "Value": 4, "Label": "Thursday" }, { "Value": 5, "Label": "Friday" }, { "Value": 6, "Label": "Saturday" }, { "Value": 7, "Label": "Sunday" } ], "Selected": "Thursday", "Selected_id": 4 }, "Units": "", "Min": 0, "Max": 0, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_CLOCK", "Index": 0, "Node": 7, "Genre": "User", "Help": "Day of Week", "ValueIDKey": 123748372, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueChanged", "TimeStamp": 1588264908}
OpenZWave/1/node/7/instance/1/commandclass/129/value/281475100459025/,{ "Label": "Hour", "Value": 2, "Units": "", "Min": 0, "Max": 255, "Type": "Byte", "Instance": 1, "CommandClass": "COMMAND_CLASS_CLOCK", "Index": 1, "Node": 7, "Genre": "User", "Help": "Hour", "ValueIDKey": 281475100459025, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueChanged", "TimeStamp": 1588264908}
OpenZWave/1/node/7/instance/1/commandclass/129/value/562950077169681/,{ "Label": "Minute", "Value": 17, "Units": "", "Min": 0, "Max": 255, "Type": "Byte", "Instance": 1, "CommandClass": "COMMAND_CLASS_CLOCK", "Index": 2, "Node": 7, "Genre": "User", "Help": "Minute", "ValueIDKey": 562950077169681, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueChanged", "TimeStamp": 1588264908}
OpenZWave/1/node/7/instance/1/commandclass/134/,{ "Instance": 1, "CommandClassId": 134, "CommandClass": "COMMAND_CLASS_VERSION", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/134/value/132218903/,{ "Label": "Library Version", "Value": "3", "Units": "", "Min": 0, "Max": 0, "Type": "String", "Instance": 1, "CommandClass": "COMMAND_CLASS_VERSION", "Index": 0, "Node": 7, "Genre": "System", "Help": "Z-Wave Library Version", "ValueIDKey": 132218903, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueChanged", "TimeStamp": 1588264905}
OpenZWave/1/node/7/instance/1/commandclass/134/value/281475108929559/,{ "Label": "Protocol Version", "Value": "3.83", "Units": "", "Min": 0, "Max": 0, "Type": "String", "Instance": 1, "CommandClass": "COMMAND_CLASS_VERSION", "Index": 1, "Node": 7, "Genre": "System", "Help": "Z-Wave Protocol Version", "ValueIDKey": 281475108929559, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueChanged", "TimeStamp": 1588264905}
OpenZWave/1/node/7/instance/1/commandclass/134/value/562950085640215/,{ "Label": "Application Version", "Value": "10.00", "Units": "", "Min": 0, "Max": 0, "Type": "String", "Instance": 1, "CommandClass": "COMMAND_CLASS_VERSION", "Index": 2, "Node": 7, "Genre": "System", "Help": "Application Version", "ValueIDKey": 562950085640215, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueChanged", "TimeStamp": 1588264905}
OpenZWave/1/node/7/instance/1/commandclass/135/,{ "Instance": 1, "CommandClassId": 135, "CommandClass": "COMMAND_CLASS_INDICATOR", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/135/value/123846673/,{ "Label": "Indicator", "Value": 0, "Units": "", "Min": 0, "Max": 255, "Type": "Byte", "Instance": 1, "CommandClass": "COMMAND_CLASS_INDICATOR", "Index": 0, "Node": 7, "Genre": "User", "Help": "Current Indicator State", "ValueIDKey": 123846673, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/49/,{ "Instance": 1, "CommandClassId": 49, "CommandClass": "COMMAND_CLASS_SENSOR_MULTILEVEL", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/49/value/281475099148306/,{ "Label": "Instance 1: Air Temperature", "Value": 73.5, "Units": "F", "Min": 0, "Max": 0, "Type": "Decimal", "Instance": 1, "CommandClass": "COMMAND_CLASS_SENSOR_MULTILEVEL", "Index": 1, "Node": 7, "Genre": "User", "Help": "Air Temperature Sensor Value", "ValueIDKey": 281475099148306, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueChanged", "TimeStamp": 1588266231}
OpenZWave/1/node/7/instance/1/commandclass/49/value/72057594168754196/,{ "Label": "Instance 1: Air Temperature Units", "Value": { "List": [ { "Value": 1, "Label": "Fahrenheit" } ], "Selected": "Fahrenheit", "Selected_id": 1 }, "Units": "", "Min": 0, "Max": 0, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_SENSOR_MULTILEVEL", "Index": 256, "Node": 7, "Genre": "System", "Help": "Air Temperature Sensor Available Units", "ValueIDKey": 72057594168754196, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/49/value/1407375005990930/,{ "Label": "Instance 1: Humidity", "Value": 55.0, "Units": "%", "Min": 0, "Max": 0, "Type": "Decimal", "Instance": 1, "CommandClass": "COMMAND_CLASS_SENSOR_MULTILEVEL", "Index": 5, "Node": 7, "Genre": "User", "Help": "Humidity Sensor Value", "ValueIDKey": 1407375005990930, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueChanged", "TimeStamp": 1588266231}
OpenZWave/1/node/7/instance/1/commandclass/49/value/73183494075596820/,{ "Label": "Instance 1: Humidity Units", "Value": { "List": [ { "Value": 0, "Label": "Percent" } ], "Selected": "Percent", "Selected_id": 0 }, "Units": "", "Min": 0, "Max": 0, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_SENSOR_MULTILEVEL", "Index": 260, "Node": 7, "Genre": "System", "Help": "Humidity Sensor Available Units", "ValueIDKey": 73183494075596820, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264893}
OpenZWave/1/node/7/instance/1/commandclass/64/,{ "Instance": 1, "CommandClassId": 64, "CommandClass": "COMMAND_CLASS_THERMOSTAT_MODE", "TimeStamp": 1588264894}
OpenZWave/1/node/7/instance/1/commandclass/64/value/122683412/,{ "Label": "Mode", "Value": { "List": [ { "Value": 0, "Label": "Off" }, { "Value": 1, "Label": "Heat" }, { "Value": 2, "Label": "Cool" }, { "Value": 3, "Label": "Auto" }, { "Value": 11, "Label": "Heat Econ" }, { "Value": 12, "Label": "Cool Econ" } ], "Selected": "Heat", "Selected_id": 1 }, "Units": "", "Min": 0, "Max": 0, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_THERMOSTAT_MODE", "Index": 0, "Node": 7, "Genre": "User", "Help": "Set the Thermostat Mode", "ValueIDKey": 122683412, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264894}
OpenZWave/1/node/7/instance/1/commandclass/67/,{ "Instance": 1, "CommandClassId": 67, "CommandClass": "COMMAND_CLASS_THERMOSTAT_SETPOINT", "TimeStamp": 1588264894}
OpenZWave/1/node/7/instance/1/commandclass/67/value/281475099443218/,{ "Label": "Heating 1", "Value": 70.0, "Units": "C", "Min": 0, "Max": 0, "Type": "Decimal", "Instance": 1, "CommandClass": "COMMAND_CLASS_THERMOSTAT_SETPOINT", "Index": 1, "Node": 7, "Genre": "User", "Help": "Set the Thermostat Setpoint Heating 1", "ValueIDKey": 281475099443218, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueChanged", "TimeStamp": 1588264906}
OpenZWave/1/node/7/instance/1/commandclass/67/value/562950076153874/,{ "Label": "Cooling 1", "Value": 78.0, "Units": "C", "Min": 0, "Max": 0, "Type": "Decimal", "Instance": 1, "CommandClass": "COMMAND_CLASS_THERMOSTAT_SETPOINT", "Index": 2, "Node": 7, "Genre": "User", "Help": "Set the Thermostat Setpoint Cooling 1", "ValueIDKey": 562950076153874, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueChanged", "TimeStamp": 1588264906}
OpenZWave/1/node/7/instance/1/commandclass/67/value/3096224866549778/,{ "Label": "Heating Econ", "Value": 62.0, "Units": "C", "Min": 0, "Max": 0, "Type": "Decimal", "Instance": 1, "CommandClass": "COMMAND_CLASS_THERMOSTAT_SETPOINT", "Index": 11, "Node": 7, "Genre": "User", "Help": "Set the Thermostat Setpoint Heating Econ", "ValueIDKey": 3096224866549778, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueChanged", "TimeStamp": 1588264906}
OpenZWave/1/node/7/instance/1/commandclass/67/value/3377699843260434/,{ "Label": "Cooling Econ", "Value": 85.0, "Units": "C", "Min": 0, "Max": 0, "Type": "Decimal", "Instance": 1, "CommandClass": "COMMAND_CLASS_THERMOSTAT_SETPOINT", "Index": 12, "Node": 7, "Genre": "User", "Help": "Set the Thermostat Setpoint Cooling Econ", "ValueIDKey": 3377699843260434, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueChanged", "TimeStamp": 1588264906}
OpenZWave/1/node/7/instance/1/commandclass/68/,{ "Instance": 1, "CommandClassId": 68, "CommandClass": "COMMAND_CLASS_THERMOSTAT_FAN_MODE", "TimeStamp": 1588264894}
OpenZWave/1/node/7/instance/1/commandclass/68/value/122748948/,{ "Label": "Fan Mode", "Value": { "List": [ { "Value": 0, "Label": "Auto Low" }, { "Value": 1, "Label": "On Low" } ], "Selected": "Auto Low", "Selected_id": 0 }, "Units": "", "Min": 0, "Max": 0, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_THERMOSTAT_FAN_MODE", "Index": 0, "Node": 7, "Genre": "User", "Help": "Set the Fan Mode", "ValueIDKey": 122748948, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264894}
OpenZWave/1/node/7/instance/2/,{ "Instance": 2, "TimeStamp": 1588264894}
OpenZWave/1/node/7/instance/2/commandclass/49/,{ "Instance": 2, "CommandClassId": 49, "CommandClass": "COMMAND_CLASS_SENSOR_MULTILEVEL", "TimeStamp": 1588264894}
OpenZWave/1/node/7/instance/2/commandclass/49/value/281475099148322/,{ "Label": "Instance 2: Air Temperature", "Value": 72.5, "Units": "F", "Min": 0, "Max": 0, "Type": "Decimal", "Instance": 2, "CommandClass": "COMMAND_CLASS_SENSOR_MULTILEVEL", "Index": 1, "Node": 7, "Genre": "User", "Help": "Air Temperature Sensor Value", "ValueIDKey": 281475099148322, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueChanged", "TimeStamp": 1588264906}
OpenZWave/1/node/7/instance/2/commandclass/49/value/72057594168754212/,{ "Label": "Instance 2: Air Temperature Units", "Value": { "List": [ { "Value": 1, "Label": "Fahrenheit" } ], "Selected": "Fahrenheit", "Selected_id": 1 }, "Units": "", "Min": 0, "Max": 0, "Type": "List", "Instance": 2, "CommandClass": "COMMAND_CLASS_SENSOR_MULTILEVEL", "Index": 256, "Node": 7, "Genre": "System", "Help": "Air Temperature Sensor Available Units", "ValueIDKey": 72057594168754212, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264894}
OpenZWave/1/node/7/instance/2/commandclass/49/value/1407375005990946/,{ "Label": "Instance 2: Humidity", "Value": 56.0, "Units": "%", "Min": 0, "Max": 0, "Type": "Decimal", "Instance": 2, "CommandClass": "COMMAND_CLASS_SENSOR_MULTILEVEL", "Index": 5, "Node": 7, "Genre": "User", "Help": "Humidity Sensor Value", "ValueIDKey": 1407375005990946, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueChanged", "TimeStamp": 1588264907}
OpenZWave/1/node/7/instance/2/commandclass/49/value/73183494075596836/,{ "Label": "Instance 2: Humidity Units", "Value": { "List": [ { "Value": 0, "Label": "Percent" } ], "Selected": "Percent", "Selected_id": 0 }, "Units": "", "Min": 0, "Max": 0, "Type": "List", "Instance": 2, "CommandClass": "COMMAND_CLASS_SENSOR_MULTILEVEL", "Index": 260, "Node": 7, "Genre": "System", "Help": "Humidity Sensor Available Units", "ValueIDKey": 73183494075596836, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588264894}
OpenZWave/1/node/7/association/1/,{ "Name": "Reporting", "Help": "", "MaxAssociations": 2, "Members": [ "1.0" ], "TimeStamp": 1588264906}
OpenZWave/1/node/16/,{ "NodeID": 16, "NodeQueryStage": "Complete", "isListening": false, "isFlirs": true, "isBeaming": true, "isRouting": true, "isSecurityv1": false, "isZWavePlus": true, "isNIFRecieved": true, "isAwake": true, "isFailed": false, "MetaData": { "OZWInfoURL": "http://www.openzwave.com/device-database/0148:0001:0003", "ZWAProductURL": "https://products.z-wavealliance.org/products/2543/", "ProductPic": "images/eurotronic/eur_spiritz.png", "Description": "• Easy control for water radiators from any Z-Wave Controller • Fits most European water radiators (wide range of additional adaptors for different manufacturers available) • FLiRS for quick response time • LED Backlit LCD • Metal nut for reliable connection to the radiator • 2 buttons for easy temperature regulation • Battery level indicator • Child Lock • Over the Air update • UK-Mode for upside down installation • Open Window detection • Automatic frost protection", "ProductManualURL": "https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2650/Spirit_Z-Wave_BAL_web_EN_view_05.pdf", "ProductPageURL": "", "InclusionHelp": "Start Inclusion mode of your primary Z-Wave Controller. Press the Boost-Button.", "ExclusionHelp": "Start Exclusion mode of your primary Z-Wave Controller. Now press and hold the boost button of the Spirit Z-Wave Plus for at least 5 seconds.", "ResetHelp": "Please use this procedure only when the network primary controller is missing or otherwise inoperable. Remove batteries. Press and hold boost button. While still holding boost button insert batteries. The LCD shows RES. Release boost button. To perform the factory reset press boost button.", "WakeupHelp": "", "ProductSupportURL": "", "Frequency": "UAE", "Name": "KOMFORTHAUS Spirit Z-Wave Plus", "ProductPicBase64": "iVBORw0KGgoAAAANSUhEUgAAAMgAAADICAIAAAAiOjnJAAAACXBIWXMAAA7EAAAOxAGVKw4bAAAgAElEQVR4nO29e5Mlx3UfeLKq7vveft1+9zQwGAzxIIknSQMgCVJeSSF6Hd6QvevY2JXlpVa78kdx7LfYcGysvQ5rHRLXBGGBpClCMiXRAiECBvEYDOY909Pd93bfvrfvoypz/8i52afOOZm3unsAQxHOiOmpm3Xy5Hn88pysrKwqpbWGWUUpZYyZSVakiKwC/PEpQna2VmcTowiBjycAkHqxskg5syOKm+5hyXDqDowx1i5nLufn8KmW/yLizez0/ASfhlSBolzEOi2KeZckSLhx6X66v4TM1vjCjOvIkeFjMRgAMgqXBDcsEqUC3HxsRT5i1wGDFJQqYArR+D6jBbwwkwnnkHDb2SJyJ8pwu9hKVyOqSuQ4lTKuU1vD3YyLo+SSOP68YXiYivggBCIrLCqwAcBHEVaZt+JdcAKiiD3mbEmPXAyuHXcKJ044fklnoj6YjJ8VsQh+IDr3E7m5y7nOBD2inoGGXK+ApoTzTK+L/hMpiY7h5pgAj3AiMHc8793HlrDilAFg2HrFJ+8car7KMxfiknN2Icb2h8XqPNweFudARHeV9mBmJhVZiZL4+IRbucpIDAxiyCU6+KIaDz+kCzXNQWQ0iHFF7IIQcN34uPdxILK5sS4KJo51XE8qCRNiEBxRuA0xHx6Vxd6dbX2mUyyT8C58VhUF4NnmpBK3F+dSWAgsPfETHivElD5WhIwUcf4kxvzAnIwjTMw1YW5cU9EUPkqiu5IiDZchIIDPVjMpw72LvguXQI9CKqQUp7lUCUdsTOkk8w2Rgh2JEvp6D2jhGz+8vrhgAbZFuBURsrgAPkfwGOYjCFAK/RJgnVbtgOf4mBPVK+7785eZvZ9Whpn+KCLD56ScUzDi34icLhKW8N9AiiQZkBAQPpB3UoCAy4P5i5Q8KDpKIh6udKw4gc9c+KwoFbeATxdc42MV7lfk7NMF1/uahAnM9PrUnk1wM9+MBIPRl30J1AjIMJmY43FzUSRRycBkRewxQCP+5AeALBPWxYc55Y/QZF7MKzl/IqFvuinO9rjiWC/ehCsFzC+uVWRQUahw3UQDETxxKQMTLE5DdCDjlYwJDvEwgHyuDYsXIHPyEE84AgIILqEPmk738CSPKILtw+HL+XOpXKeEkvgxoJc7dbLyjvvjUQe7E/JjAvLO9tFgKYl1uKrcNIAGB+mO8OFMeBcBkHFnY7FF2HGvzxxOIFlJDD++Vpyta+VrSOzAXQN5iPiyU0Br1yo37EByMOn4VKdmnj0P8eehnE1gHphFVg/XGp+xbb3rWKcSSzwrmu+/ls9P+VSdEsE0ePqyXpEiyifmlOKShYnFOMwHyWnL2VqJYpBJwhn6mqmjSHker51NWlGqCGfcmRxPa3eetmc2ITke8h7CA4D3xSccpy1hIwT+YsGwPQNi4HAuGnmmjtxWhK0of7hSrA/HNj6XBwCltQ774PwBM5BhCzYnxjobK6LIOaWayf/MTT6H04YziJTwxuGgx32MD8jQESdw4fxI+HAawpZc94k0RAbI44kLxtmKZ8lBwCxckplTjoBZsLIFO+JWFeXnHEje8NlHsIy9pUMsWPA6RRz03NCiUYpcIhQhmylkkRJgeNrA9hBlI0bDzQNScXoCnYIiic7iIvlY0eWGsJJFzvr65oKKMCqopwhfQi8SzAR3QMHA8Cie1IoD5VROOYM6wGzuk6c4c0cZWoMurljYguecNJyz+cMqxYfWGXgWx+UZmD9EyuJFuCvEs6lPgsDkA4Lpn5BBgekRlyTAiosxc5Ixs3A5sSRhsX0mCuglahcQ1RcFcVuiNY9VYuoUmfh8epIK7VVhONT7Qi4P4KKPIe9ssbkvQRRMdqJU4jDgpieUxeccYr4InPVJReqLSBXwkc8sPj6Q9yChLJh2+Nmzp8KZUPBJedrAG4BjuNXMPC7ymZmVfBAHz3B6KKxm6jhzPHzahXTk3UHKUwxuXzB9BAqPtMXP+iTk9L4MGO5UJCuesknXkIeaKNhMHcWc6BMpnEAD0VGUE/KGDUviaiIRzq4PEicoKqcEalpcHwoVTm9ZOZk4JT7r/mJVeeERiLfl8hMOAWc7kbit+HEAN9wmuB7/BORREUlOYK4d6YXwJL3g5lxgMb5gVriVq4kg71oOJgIX3LGYTTjqeeEYwtJzo2CUE8SLGvLmkPcKPxb5k45Ef/iMrjxJnxsQH/uGLpGTiydqjWXAfyE/TrD1OLZ86nDVsCKUS8AHPkY+7gH68ISgyByFUIpseXMx4BfRa6b6xe0jxpiApqfqNGzYmYJBMMCfqhSaY7kaLMF/wcJl+zyw/ZSkOmcpLlVByoJkJw+sBuK8LS5nhSMwEYIc88DuaxWQissQZlXkmKc8X334mHAgmau4tJg5YRhmRU758ho/wFNeYJbnUVbU0dWfPKVD5hZEMWJBLrqINp5YxXkb+cltwaXic3/RCr6+xCTC9RK5YQmJamTWgtly9wArvkjgxnNgUuuKOAclfnR8RK25uQiNKAOhKfRcIbFRgKxgJVeDz5yKB3DI+4/4gJwKHweEnClGwY7sX6211jpN0yzL7Bp1HMdxHCdJEkWRj3PxfgP0pIYPfi5tuBfZ7yKwiqDhbJXFeZ6tPERWYW5n6MgYk2WZRZILb1EUWRdkWWYtn0xLAGGfhpo4lp9hhFOe4uRdjNikY7GJmCNEjEM+H3G2POrwUYUpxQwVTj1cTpAsGxaVm4V3aoyZTCZpmnLVXAADAIski7Aoihy8cAojUvnswMUWJecAEvFUxAj0rJsfkDZEGtErAUoRCqK2hFhsHgC62HymbBysYo7w+Y/0G0Cwy3eErW9wZllmkWSjmgtgOHoV9M7Ms0UK8R0EoZLTxcbkQDNxNIMEmiIA4h2Jg4bXC2OiQFwJm0yECDCMBtryse5otNaTyaTgu4Mhj0g763JgskAslUpOsMB4KKKvWBMgEJ2FaTjl7LfN+Line truncated
OpenZWave/1/node/16/instance/1/,{ "Instance": 1, "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/38/,{ "Instance": 1, "CommandClassId": 38, "CommandClass": "COMMAND_CLASS_SWITCH_MULTILEVEL", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/38/value/273252369/,{ "Label": "Level", "Value": 94, "Units": "%", "Min": 0, "Max": 100, "Type": "Byte", "Instance": 1, "CommandClass": "COMMAND_CLASS_SWITCH_MULTILEVEL", "Index": 0, "Node": 16, "Genre": "User", "Help": "The Current Level of the Device", "ValueIDKey": 273252369, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueChanged", "TimeStamp": 1588422759}
OpenZWave/1/node/16/instance/1/commandclass/38/value/281475249963032/,{ "Label": "Up", "Value": false, "Units": "", "Min": 0, "Max": 0, "Type": "Button", "Instance": 1, "CommandClass": "COMMAND_CLASS_SWITCH_MULTILEVEL", "Index": 1, "Node": 16, "Genre": "User", "Help": "Increase the Brightness of the Device", "ValueIDKey": 281475249963032, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/38/value/562950226673688/,{ "Label": "Down", "Value": false, "Units": "", "Min": 0, "Max": 0, "Type": "Button", "Instance": 1, "CommandClass": "COMMAND_CLASS_SWITCH_MULTILEVEL", "Index": 2, "Node": 16, "Genre": "User", "Help": "Decrease the Brightness of the Device", "ValueIDKey": 562950226673688, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/38/value/844425211772944/,{ "Label": "Ignore Start Level", "Value": true, "Units": "", "Min": 0, "Max": 0, "Type": "Bool", "Instance": 1, "CommandClass": "COMMAND_CLASS_SWITCH_MULTILEVEL", "Index": 3, "Node": 16, "Genre": "System", "Help": "Ignore the Start Level of the Device when increasing/decreasing brightness", "ValueIDKey": 844425211772944, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/38/value/1125900188483601/,{ "Label": "Start Level", "Value": 0, "Units": "", "Min": 0, "Max": 255, "Type": "Byte", "Instance": 1, "CommandClass": "COMMAND_CLASS_SWITCH_MULTILEVEL", "Index": 4, "Node": 16, "Genre": "System", "Help": "Start Level when Changing the Brightness of a Device", "ValueIDKey": 1125900188483601, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/64/,{ "Instance": 1, "CommandClassId": 64, "CommandClass": "COMMAND_CLASS_THERMOSTAT_MODE", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/64/value/273678356/,{ "Label": "Mode", "Value": { "List": [ { "Value": 0, "Label": "Off" }, { "Value": 1, "Label": "Heat" }, { "Value": 11, "Label": "Heat Eco" }, { "Value": 15, "Label": "Full Power" }, { "Value": 31, "Label": "Manufacturer Specific" } ], "Selected": "Heat", "Selected_id": 1 }, "Units": "", "Min": 0, "Max": 0, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_THERMOSTAT_MODE", "Index": 0, "Node": 16, "Genre": "User", "Help": "Off: No heating, only frost protection. Heat: Room temperature will be kept at the configured setpoint. Heat Eco: Energy save heating mode. Room temperature will be lowered to the configured eco setpoint in order to save energy. Full Power: Full power heating. This mode is left automatically after 5 minutes. Manufacturer Specific: Direct valve control mode. The valve opening percentage can be controlled using the switch multilevel command class.", "ValueIDKey": 273678356, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/67/,{ "Instance": 1, "CommandClassId": 67, "CommandClass": "COMMAND_CLASS_THERMOSTAT_SETPOINT", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/67/value/281475250438162/,{ "Label": "Heating 1", "Value": 19.0, "Units": "C", "Min": 8, "Max": 28, "Type": "Decimal", "Instance": 1, "CommandClass": "COMMAND_CLASS_THERMOSTAT_SETPOINT", "Index": 1, "Node": 16, "Genre": "User", "Help": "Set the Thermostat Setpoint Heating 1", "ValueIDKey": 281475250438162, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/67/value/3096225017544722/,{ "Label": "Heating Econ", "Value": 18.0, "Units": "C", "Min": 8, "Max": 28, "Type": "Decimal", "Instance": 1, "CommandClass": "COMMAND_CLASS_THERMOSTAT_SETPOINT", "Index": 11, "Node": 16, "Genre": "User", "Help": "Set the Thermostat Setpoint Heating Econ", "ValueIDKey": 3096225017544722, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/67/value/28428972921503762/,{ "Label": "Heating 1_minimum", "Value": 8.0, "Units": "C", "Min": 0, "Max": 0, "Type": "Decimal", "Instance": 1, "CommandClass": "COMMAND_CLASS_THERMOSTAT_SETPOINT", "Index": 101, "Node": 16, "Genre": "User", "Help": "", "ValueIDKey": 28428972921503762, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/67/value/56576470592569362/,{ "Label": "Heating 1_maximum", "Value": 28.0, "Units": "C", "Min": 0, "Max": 0, "Type": "Decimal", "Instance": 1, "CommandClass": "COMMAND_CLASS_THERMOSTAT_SETPOINT", "Index": 201, "Node": 16, "Genre": "User", "Help": "", "ValueIDKey": 56576470592569362, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/67/value/31243722688610322/,{ "Label": "Heating Econ_minimum", "Value": 8.0, "Units": "C", "Min": 0, "Max": 0, "Type": "Decimal", "Instance": 1, "CommandClass": "COMMAND_CLASS_THERMOSTAT_SETPOINT", "Index": 111, "Node": 16, "Genre": "User", "Help": "", "ValueIDKey": 31243722688610322, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/67/value/59391220359675922/,{ "Label": "Heating Econ_maximum", "Value": 28.0, "Units": "C", "Min": 0, "Max": 0, "Type": "Decimal", "Instance": 1, "CommandClass": "COMMAND_CLASS_THERMOSTAT_SETPOINT", "Index": 211, "Node": 16, "Genre": "User", "Help": "", "ValueIDKey": 59391220359675922, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/112/,{ "Instance": 1, "CommandClassId": 112, "CommandClass": "COMMAND_CLASS_CONFIGURATION", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/112/value/281475255369748/,{ "Label": "LCD Invert", "Value": { "List": [ { "Value": 0, "Label": "Normal" }, { "Value": 1, "Label": "Upside Down" } ], "Selected": "Normal", "Selected_id": 0 }, "Units": "", "Min": 0, "Max": 1, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_CONFIGURATION", "Index": 1, "Node": 16, "Genre": "Config", "Help": "Allows rotating the LCD contents by 180 degrees. Default: Normal", "ValueIDKey": 281475255369748, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/112/value/562950232080401/,{ "Label": "LCD Timeout", "Value": 0, "Units": "sec", "Min": 0, "Max": 30, "Type": "Byte", "Instance": 1, "CommandClass": "COMMAND_CLASS_CONFIGURATION", "Index": 2, "Node": 16, "Genre": "Config", "Help": "0: No Timeout, LCD always on. 5-30: Timeout after 5-30s. Default: 0 (LCD always on)", "ValueIDKey": 562950232080401, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/112/value/844425208791060/,{ "Label": "Backlight", "Value": { "List": [ { "Value": 0, "Label": "Backlight disabled" }, { "Value": 1, "Label": "Backlight enabled" } ], "Selected": "Backlight enabled", "Selected_id": 1 }, "Units": "", "Min": 0, "Max": 1, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_CONFIGURATION", "Index": 3, "Node": 16, "Genre": "Config", "Help": "Default: Backlight enabled", "ValueIDKey": 844425208791060, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/112/value/1125900185501716/,{ "Label": "Battery Report", "Value": { "List": [ { "Value": 0, "Label": "Only send battery status as notification" }, { "Value": 1, "Label": "Send once a day" } ], "Selected": "Send once a day", "Selected_id": 1 }, "Units": "", "Min": 0, "Max": 1, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_CONFIGURATION", "Index": 4, "Node": 16, "Genre": "Config", "Help": "Default: Send once a day", "ValueIDKey": 1125900185501716, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/112/value/1407375162212369/,{ "Label": "Temperature Report Threshold", "Value": 1, "Units": "0.1°C", "Min": 0, "Max": 50, "Type": "Byte", "Instance": 1, "CommandClass": "COMMAND_CLASS_CONFIGURATION", "Index": 5, "Node": 16, "Genre": "Config", "Help": "0: Don't send temperature automatically. 1-50: Report temperature at 0.1-5.0°C temperature difference. Default: 5 (Delta = 0.5°C)", "ValueIDKey": 1407375162212369, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueChanged", "TimeStamp": 1588422810}
OpenZWave/1/node/16/instance/1/commandclass/112/value/1688850138923025/,{ "Label": "Valve Opening Percentage Report", "Value": 5, "Units": "", "Min": 0, "Max": 100, "Type": "Byte", "Instance": 1, "CommandClass": "COMMAND_CLASS_CONFIGURATION", "Index": 6, "Node": 16, "Genre": "Config", "Help": "0: Don't send Valve opening percentage automatically. 1-100: Report valve opening percentage at a delta of 1-100%. Default: 0", "ValueIDKey": 1688850138923025, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueChanged", "TimeStamp": 1588422811}
OpenZWave/1/node/16/instance/1/commandclass/112/value/1970325115633684/,{ "Label": "Open Window Detection", "Value": { "List": [ { "Value": 0, "Label": "Disabled" }, { "Value": 1, "Label": "Low sensibility" }, { "Value": 2, "Label": "Medium sensibility" }, { "Value": 3, "Label": "High sensibility" } ], "Selected": "Medium sensibility", "Selected_id": 2 }, "Units": "", "Min": 0, "Max": 3, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_CONFIGURATION", "Index": 7, "Node": 16, "Genre": "Config", "Help": "Default: Medium sensibility", "ValueIDKey": 1970325115633684, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/112/value/2251800092344337/,{ "Label": "Measured Temperature Offset", "Value": 0, "Units": "", "Min": 0, "Max": 255, "Type": "Byte", "Instance": 1, "CommandClass": "COMMAND_CLASS_CONFIGURATION", "Index": 8, "Node": 16, "Genre": "Config", "Help": "206-255: -5.0 to -0.1°C. 0-50: 0°C-5°C. 128: External Temperature Sensor. Default: 0 (0.0°C Offset)", "ValueIDKey": 2251800092344337, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/94/,{ "Instance": 1, "CommandClassId": 94, "CommandClass": "COMMAND_CLASS_ZWAVEPLUS_INFO", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/94/value/282558481/,{ "Label": "ZWave+ Version", "Value": 1, "Units": "", "Min": 0, "Max": 255, "Type": "Byte", "Instance": 1, "CommandClass": "COMMAND_CLASS_ZWAVEPLUS_INFO", "Index": 0, "Node": 16, "Genre": "System", "Help": "ZWave+ Version Supported on the Device", "ValueIDKey": 282558481, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/94/value/281475259269142/,{ "Label": "InstallerIcon", "Value": 4608, "Units": "", "Min": -32768, "Max": 32767, "Type": "Short", "Instance": 1, "CommandClass": "COMMAND_CLASS_ZWAVEPLUS_INFO", "Index": 1, "Node": 16, "Genre": "System", "Help": "Icon File to use for the Installer Application", "ValueIDKey": 281475259269142, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/94/value/562950235979798/,{ "Label": "UserIcon", "Value": 4608, "Units": "", "Min": -32768, "Max": 32767, "Type": "Short", "Instance": 1, "CommandClass": "COMMAND_CLASS_ZWAVEPLUS_INFO", "Index": 2, "Node": 16, "Genre": "System", "Help": "Icon File to use for the User Application", "ValueIDKey": 562950235979798, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/114/,{ "Instance": 1, "CommandClassId": 114, "CommandClass": "COMMAND_CLASS_MANUFACTURER_SPECIFIC", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/114/value/282886163/,{ "Label": "Loaded Config Revision", "Value": 0, "Units": "", "Min": -2147483648, "Max": 2147483647, "Type": "Int", "Instance": 1, "CommandClass": "COMMAND_CLASS_MANUFACTURER_SPECIFIC", "Index": 0, "Node": 16, "Genre": "System", "Help": "Revision of the Config file currently loaded", "ValueIDKey": 282886163, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/114/value/281475259596819/,{ "Label": "Config File Revision", "Value": 5, "Units": "", "Min": -2147483648, "Max": 2147483647, "Type": "Int", "Instance": 1, "CommandClass": "COMMAND_CLASS_MANUFACTURER_SPECIFIC", "Index": 1, "Node": 16, "Genre": "System", "Help": "Revision of the Config file on the File System", "ValueIDKey": 281475259596819, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/114/value/562950236307475/,{ "Label": "Latest Available Config File Revision", "Value": 5, "Units": "", "Min": -2147483648, "Max": 2147483647, "Type": "Int", "Instance": 1, "CommandClass": "COMMAND_CLASS_MANUFACTURER_SPECIFIC", "Index": 2, "Node": 16, "Genre": "System", "Help": "Latest Revision of the Config file available for download", "ValueIDKey": 562950236307475, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/114/value/844425213018135/,{ "Label": "Device ID", "Value": "", "Units": "", "Min": 0, "Max": 0, "Type": "String", "Instance": 1, "CommandClass": "COMMAND_CLASS_MANUFACTURER_SPECIFIC", "Index": 3, "Node": 16, "Genre": "System", "Help": "Manufacturer Specific Device ID/Model", "ValueIDKey": 844425213018135, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/114/value/1125900189728791/,{ "Label": "Serial Number", "Value": "", "Units": "", "Min": 0, "Max": 0, "Type": "String", "Instance": 1, "CommandClass": "COMMAND_CLASS_MANUFACTURER_SPECIFIC", "Index": 4, "Node": 16, "Genre": "System", "Help": "Device Serial Number", "ValueIDKey": 1125900189728791, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/115/,{ "Instance": 1, "CommandClassId": 115, "CommandClass": "COMMAND_CLASS_POWERLEVEL", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/115/value/282902548/,{ "Label": "Powerlevel", "Value": { "List": [ { "Value": 0, "Label": "Normal" }, { "Value": 1, "Label": "-1dB" }, { "Value": 2, "Label": "-2dB" }, { "Value": 3, "Label": "-3dB" }, { "Value": 4, "Label": "-4dB" }, { "Value": 5, "Label": "-5dB" }, { "Value": 6, "Label": "-6dB" }, { "Value": 7, "Label": "-7dB" }, { "Value": 8, "Label": "-8dB" }, { "Value": 9, "Label": "-9dB" } ], "Selected": "Normal", "Selected_id": 0 }, "Units": "dB", "Min": 0, "Max": 0, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_POWERLEVEL", "Index": 0, "Node": 16, "Genre": "System", "Help": "Output RF PowerLevel", "ValueIDKey": 282902548, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/115/value/281475259613201/,{ "Label": "Timeout", "Value": 0, "Units": "seconds", "Min": 0, "Max": 255, "Type": "Byte", "Instance": 1, "CommandClass": "COMMAND_CLASS_POWERLEVEL", "Index": 1, "Node": 16, "Genre": "System", "Help": "Timeout till the PowerLevel is reset to Normal", "ValueIDKey": 281475259613201, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/115/value/562950236323864/,{ "Label": "Set Powerlevel", "Value": false, "Units": "", "Min": 0, "Max": 0, "Type": "Button", "Instance": 1, "CommandClass": "COMMAND_CLASS_POWERLEVEL", "Index": 2, "Node": 16, "Genre": "System", "Help": "Apply the Output PowerLevel and Timeout Values", "ValueIDKey": 562950236323864, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/115/value/844425213034513/,{ "Label": "Test Node", "Value": 0, "Units": "", "Min": 0, "Max": 255, "Type": "Byte", "Instance": 1, "CommandClass": "COMMAND_CLASS_POWERLEVEL", "Index": 3, "Node": 16, "Genre": "System", "Help": "Node to Perform a test against", "ValueIDKey": 844425213034513, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/115/value/1125900189745172/,{ "Label": "Test Powerlevel", "Value": { "List": [ { "Value": 0, "Label": "Normal" }, { "Value": 1, "Label": "-1dB" }, { "Value": 2, "Label": "-2dB" }, { "Value": 3, "Label": "-3dB" }, { "Value": 4, "Label": "-4dB" }, { "Value": 5, "Label": "-5dB" }, { "Value": 6, "Label": "-6dB" }, { "Value": 7, "Label": "-7dB" }, { "Value": 8, "Label": "-8dB" }, { "Value": 9, "Label": "-9dB" } ], "Selected": "Normal", "Selected_id": 0 }, "Units": "dB", "Min": 0, "Max": 0, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_POWERLEVEL", "Index": 4, "Node": 16, "Genre": "System", "Help": "PowerLevel to use for the Test", "ValueIDKey": 1125900189745172, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/115/value/1407375166455830/,{ "Label": "Frame Count", "Value": 0, "Units": "", "Min": -32768, "Max": 32767, "Type": "Short", "Instance": 1, "CommandClass": "COMMAND_CLASS_POWERLEVEL", "Index": 5, "Node": 16, "Genre": "System", "Help": "How Many Messages to send to the Node for the Test", "ValueIDKey": 1407375166455830, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/115/value/1688850143166488/,{ "Label": "Test", "Value": false, "Units": "", "Min": 0, "Max": 0, "Type": "Button", "Instance": 1, "CommandClass": "COMMAND_CLASS_POWERLEVEL", "Index": 6, "Node": 16, "Genre": "System", "Help": "Perform a PowerLevel Test against the a Node", "ValueIDKey": 1688850143166488, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/115/value/1970325119877144/,{ "Label": "Report", "Value": false, "Units": "", "Min": 0, "Max": 0, "Type": "Button", "Instance": 1, "CommandClass": "COMMAND_CLASS_POWERLEVEL", "Index": 7, "Node": 16, "Genre": "System", "Help": "Get the results of the latest PowerLevel Test against a Node", "ValueIDKey": 1970325119877144, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/115/value/2251800096587796/,{ "Label": "Test Status", "Value": { "List": [ { "Value": 0, "Label": "Failed" }, { "Value": 1, "Label": "Success" }, { "Value": 2, "Label": "In Progress" } ], "Selected": "Failed", "Selected_id": 0 }, "Units": "", "Min": 0, "Max": 0, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_POWERLEVEL", "Index": 8, "Node": 16, "Genre": "System", "Help": "The Current Status of the last PowerNode Test Executed", "ValueIDKey": 2251800096587796, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/115/value/2533275073298454/,{ "Label": "Acked Frames", "Value": 0, "Units": "", "Min": -32768, "Max": 32767, "Type": "Short", "Instance": 1, "CommandClass": "COMMAND_CLASS_POWERLEVEL", "Index": 9, "Node": 16, "Genre": "System", "Help": "Number of Messages successfully Acked by the Target Node", "ValueIDKey": 2533275073298454, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/117/,{ "Instance": 1, "CommandClassId": 117, "CommandClass": "COMMAND_CLASS_PROTECTION", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/117/value/282935316/,{ "Label": "Protection", "Value": { "List": [ { "Value": 0, "Label": "Unprotected" }, { "Value": 1, "Label": "Protection by Sequence" }, { "Value": 2, "Label": "No Operation Possible" } ], "Selected": "Protection by Sequence", "Selected_id": 1 }, "Units": "", "Min": 0, "Max": 0, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_PROTECTION", "Index": 0, "Node": 16, "Genre": "System", "Help": "Protect a device against unintentional control", "ValueIDKey": 282935316, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/128/,{ "Instance": 1, "CommandClassId": 128, "CommandClass": "COMMAND_CLASS_BATTERY", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/128/value/274726929/,{ "Label": "Battery Level", "Value": 90, "Units": "%", "Min": 0, "Max": 255, "Type": "Byte", "Instance": 1, "CommandClass": "COMMAND_CLASS_BATTERY", "Index": 0, "Node": 16, "Genre": "User", "Help": "Current Battery Level", "ValueIDKey": 274726929, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/134/,{ "Instance": 1, "CommandClassId": 134, "CommandClass": "COMMAND_CLASS_VERSION", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/134/value/283213847/,{ "Label": "Library Version", "Value": "3", "Units": "", "Min": 0, "Max": 0, "Type": "String", "Instance": 1, "CommandClass": "COMMAND_CLASS_VERSION", "Index": 0, "Node": 16, "Genre": "System", "Help": "Z-Wave Library Version", "ValueIDKey": 283213847, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/134/value/281475259924503/,{ "Label": "Protocol Version", "Value": "4.61", "Units": "", "Min": 0, "Max": 0, "Type": "String", "Instance": 1, "CommandClass": "COMMAND_CLASS_VERSION", "Index": 1, "Node": 16, "Genre": "System", "Help": "Z-Wave Protocol Version", "ValueIDKey": 281475259924503, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/134/value/562950236635159/,{ "Label": "Application Version", "Value": "0.15", "Units": "", "Min": 0, "Max": 0, "Type": "String", "Instance": 1, "CommandClass": "COMMAND_CLASS_VERSION", "Index": 2, "Node": 16, "Genre": "System", "Help": "Application Version", "ValueIDKey": 562950236635159, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/152/,{ "Instance": 1, "CommandClassId": 152, "CommandClass": "COMMAND_CLASS_SECURITY", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/152/value/283508752/,{ "Label": "Secured", "Value": true, "Units": "", "Min": 0, "Max": 0, "Type": "Bool", "Instance": 1, "CommandClass": "COMMAND_CLASS_SECURITY", "Index": 0, "Node": 16, "Genre": "System", "Help": "Is Communication with Device Encrypted", "ValueIDKey": 283508752, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/49/,{ "Instance": 1, "CommandClassId": 49, "CommandClass": "COMMAND_CLASS_SENSOR_MULTILEVEL", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/49/value/281475250143250/,{ "Label": "Air Temperature", "Value": 17.260000228881837, "Units": "C", "Min": 0, "Max": 0, "Type": "Decimal", "Instance": 1, "CommandClass": "COMMAND_CLASS_SENSOR_MULTILEVEL", "Index": 1, "Node": 16, "Genre": "User", "Help": "Air Temperature Sensor Value", "ValueIDKey": 281475250143250, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueChanged", "TimeStamp": 1588422760}
OpenZWave/1/node/16/instance/1/commandclass/49/value/72057594319749140/,{ "Label": "Air Temperature Units", "Value": { "List": [ { "Value": 0, "Label": "Celsius" } ], "Selected": "Celsius", "Selected_id": 0 }, "Units": "", "Min": 0, "Max": 0, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_SENSOR_MULTILEVEL", "Index": 256, "Node": 16, "Genre": "System", "Help": "Air Temperature Sensor Available Units", "ValueIDKey": 72057594319749140, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/113/,{ "Instance": 1, "CommandClassId": 113, "CommandClass": "COMMAND_CLASS_NOTIFICATION", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/113/value/72057594312409105/,{ "Label": "Previous Event Cleared", "Value": 0, "Units": "", "Min": 0, "Max": 255, "Type": "Byte", "Instance": 1, "CommandClass": "COMMAND_CLASS_NOTIFICATION", "Index": 256, "Node": 16, "Genre": "User", "Help": "Previous Event that was sent", "ValueIDKey": 72057594312409105, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/113/value/2251800088166420/,{ "Label": "Power Management", "Value": { "List": [ { "Value": 0, "Label": "Clear" }, { "Value": 10, "Label": "Replace Battery Soon" }, { "Value": 11, "Label": "Replace Battery Now" } ], "Selected": "Clear", "Selected_id": 0 }, "Units": "", "Min": 0, "Max": 0, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_NOTIFICATION", "Index": 8, "Node": 16, "Genre": "User", "Help": "Power Management Alerts", "ValueIDKey": 2251800088166420, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/113/value/74872344079515671/,{ "Label": "Error Code", "Value": "", "Units": "", "Min": 0, "Max": 0, "Type": "String", "Instance": 1, "CommandClass": "COMMAND_CLASS_NOTIFICATION", "Index": 266, "Node": 16, "Genre": "User", "Help": "The Error Code returned by the device", "ValueIDKey": 74872344079515671, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/instance/1/commandclass/113/value/2533275064877076/,{ "Label": "System", "Value": { "List": [ { "Value": 0, "Label": "Clear" }, { "Value": 3, "Label": "Hardware Failure Code" } ], "Selected": "Clear", "Selected_id": 0 }, "Units": "", "Min": 0, "Max": 0, "Type": "List", "Instance": 1, "CommandClass": "COMMAND_CLASS_NOTIFICATION", "Index": 9, "Node": 16, "Genre": "User", "Help": "System Alerts", "ValueIDKey": 2533275064877076, "ReadOnly": false, "WriteOnly": false, "ValueSet": false, "ValuePolled": false, "ChangeVerified": false, "Event": "valueAdded", "TimeStamp": 1588422682}
OpenZWave/1/node/16/association/1/,{ "Name": "Group 1", "Help": "", "MaxAssociations": 1, "Members": [ "1.0" ], "TimeStamp": 1588422682}