Ryan Nowakowski 5ceb4c404d Fix radiotherm model CT50 (#8181)
Model CT50 has an "Auto" mode.  When mode is set to auto we need to ask
what the current state is: cool or heat.  Then we can query the
appropriate target temperature.

Without this fix, the target temperature shows up blank in the UI and
setting the mode fails.